Purpose: Current mechanical ventilation practices for patients with acute brain injury (ABI) are poorly defined. This study aimed to describe ventilator settings/parameters used in intensive care units (ICUs) and evaluate their association with clinical outcomes in these patients. Methods: An international, prospective, multicenter, observational study was conducted across 74 ICUs in 26 countries, including adult patients with ABI (e.g., traumatic brain injury, intracranial hemorrhage, subarachnoid hemorrhage, and acute ischemic stroke), who required ICU admission and invasive mechanical ventilation. Ventilatory settings were recorded daily during the first week and on days 10 and 14. ICU and 6-months mortality and 6-months neurological outcome were evaluated. Results: On admission, 2095 recruited patients (median age 58 [interquartile range 45-70] years, 66.1% male) had a median plateau pressure (Pplat) of 15 (13-18) cmH20, tidal volume/predicted body weight 6.5 (5.7-7.3) mL/Kg, driving pressure 9 (7-12) cmH20, and positive end-expiratory pressure 5 (5-8) cmH20, with no modifications in case of increased intracranial pressure (> 20 mmHg). Significant differences in practices were observed across different countries. The majority of these ventilatory settings were associated with ICU mortality, with the highest hazard ratio (HR) for Pplat (odds ratio 1.50; 95% confidence interval, CI: 1.27-1.78). The results demonstrated consistent association with 6-month mortality; less clear association was observed for neurological outcome. Conclusions: Protective ventilation strategies are commonly used in ABI patients but with high variability across different countries. Ventilator settings during ICU stay were associated with an increased risk of ICU and 6-month mortality, but not an unfavorable neurological outcome.

Robba, C., Giardiello, D., Almondo, C., Asehnoune, K., Badenes, R., Cinotti, R., et al. (2025). Ventilation practices in acute brain injured patients and association with outcomes: the VENTIBRAIN multicenter observational study. INTENSIVE CARE MEDICINE [10.1007/s00134-025-07808-1].

Ventilation practices in acute brain injured patients and association with outcomes: the VENTIBRAIN multicenter observational study

Giardiello, Daniele;Graziano, Francesca;Rebora, Paola;Galimberti, Stefania;Citerio, Giuseppe;Mangili, Paolo
Membro del Collaboration Group
;
Piazza, Valentina
Membro del Collaboration Group
;
Friz, Melisa Juliana Polo
Membro del Collaboration Group
;
del Bianco, Silvia
Membro del Collaboration Group
;
Addis, Alberto
Membro del Collaboration Group
;
Fossi, Francesca
Membro del Collaboration Group
;
Chieregato, Arturo
Membro del Collaboration Group
;
Bortolaso, Anna
Membro del Collaboration Group
;
Bosa, Linda
Membro del Collaboration Group
;
Gritti, Paolo
Membro del Collaboration Group
;
2025

Abstract

Purpose: Current mechanical ventilation practices for patients with acute brain injury (ABI) are poorly defined. This study aimed to describe ventilator settings/parameters used in intensive care units (ICUs) and evaluate their association with clinical outcomes in these patients. Methods: An international, prospective, multicenter, observational study was conducted across 74 ICUs in 26 countries, including adult patients with ABI (e.g., traumatic brain injury, intracranial hemorrhage, subarachnoid hemorrhage, and acute ischemic stroke), who required ICU admission and invasive mechanical ventilation. Ventilatory settings were recorded daily during the first week and on days 10 and 14. ICU and 6-months mortality and 6-months neurological outcome were evaluated. Results: On admission, 2095 recruited patients (median age 58 [interquartile range 45-70] years, 66.1% male) had a median plateau pressure (Pplat) of 15 (13-18) cmH20, tidal volume/predicted body weight 6.5 (5.7-7.3) mL/Kg, driving pressure 9 (7-12) cmH20, and positive end-expiratory pressure 5 (5-8) cmH20, with no modifications in case of increased intracranial pressure (> 20 mmHg). Significant differences in practices were observed across different countries. The majority of these ventilatory settings were associated with ICU mortality, with the highest hazard ratio (HR) for Pplat (odds ratio 1.50; 95% confidence interval, CI: 1.27-1.78). The results demonstrated consistent association with 6-month mortality; less clear association was observed for neurological outcome. Conclusions: Protective ventilation strategies are commonly used in ABI patients but with high variability across different countries. Ventilator settings during ICU stay were associated with an increased risk of ICU and 6-month mortality, but not an unfavorable neurological outcome.
Articolo in rivista - Articolo scientifico
Acute brain injury; Cerebrovascular disease; Mechanical ventilation; Outcome; Traumatic brain injury
English
24-feb-2025
2025
open
Robba, C., Giardiello, D., Almondo, C., Asehnoune, K., Badenes, R., Cinotti, R., et al. (2025). Ventilation practices in acute brain injured patients and association with outcomes: the VENTIBRAIN multicenter observational study. INTENSIVE CARE MEDICINE [10.1007/s00134-025-07808-1].
File in questo prodotto:
File Dimensione Formato  
Robba-2025-Int Care Med-VoR.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 1.82 MB
Formato Adobe PDF
1.82 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/542543
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
Social impact