We present measurements aimed to characterize the Hamamatsu R7600 multi anode Photon Multiplier Tube (PMT), in view of its application for a new generation of Ring Imaging Cherenkov (RICH) detectors at LHCb. Single photon signals were used as tools for characterization. A commercial blue LED slightly forward biased was the main source of photon light. Spectra obtained with this source coincided with those obtained with the Cherenkov light from a PbF 2 crystal and a 22Na gamma source. Dark current and cross-talk performances were measured. PMT response was studied for single photon signals as a function of the dynodes bias level ratio and magnetic field. Results obtained so far showed that the R7600 PMTs are adequate for the LHCb RICH detectors at high luminosity. © 2010 IEEE.
Arnaboldi, C., Calvi, M., Fanchini, E., Giachero, A., Gotti, C., Maino, M., et al. (2010). Characterization of a Hamamatsu R7600 multi-anode photomultiplier tube with single photon signals. In IEEE Nuclear Science Symposium Conference Record (pp.1124-1129). IEEE [10.1109/NSSMIC.2010.5873942].
Characterization of a Hamamatsu R7600 multi-anode photomultiplier tube with single photon signals
ARNABOLDI, CLAUDIO
;CALVI, MARTASecondo
;FANCHINI, ERICA;GIACHERO, ANDREA;GOTTI, CLAUDIO;MAINO, MATTEO;PEREGO, DAVIDE LUIGIPenultimo
;PESSINA, GIANLUIGI EZIOUltimo
2010
Abstract
We present measurements aimed to characterize the Hamamatsu R7600 multi anode Photon Multiplier Tube (PMT), in view of its application for a new generation of Ring Imaging Cherenkov (RICH) detectors at LHCb. Single photon signals were used as tools for characterization. A commercial blue LED slightly forward biased was the main source of photon light. Spectra obtained with this source coincided with those obtained with the Cherenkov light from a PbF 2 crystal and a 22Na gamma source. Dark current and cross-talk performances were measured. PMT response was studied for single photon signals as a function of the dynodes bias level ratio and magnetic field. Results obtained so far showed that the R7600 PMTs are adequate for the LHCb RICH detectors at high luminosity. © 2010 IEEE.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.