We present measurements aimed to characterize the Hamamatsu R7600 multi anode Photon Multiplier Tube (PMT), in view of its application for a new generation of Ring Imaging Cherenkov (RICH) detectors at LHCb. Single photon signals were used as tools for characterization. A commercial blue LED slightly forward biased was the main source of photon light. Spectra obtained with this source coincided with those obtained with the Cherenkov light from a PbF 2 crystal and a 22Na gamma source. Dark current and cross-talk performances were measured. PMT response was studied for single photon signals as a function of the dynodes bias level ratio and magnetic field. Results obtained so far showed that the R7600 PMTs are adequate for the LHCb RICH detectors at high luminosity. © 2010 IEEE.

Arnaboldi, C., Calvi, M., Fanchini, E., Giachero, A., Gotti, C., Maino, M., et al. (2010). Characterization of a Hamamatsu R7600 multi-anode photomultiplier tube with single photon signals. In IEEE Nuclear Science Symposium Conference Record (pp.1124-1129). IEEE [10.1109/NSSMIC.2010.5873942].

Characterization of a Hamamatsu R7600 multi-anode photomultiplier tube with single photon signals

ARNABOLDI, CLAUDIO
;
CALVI, MARTA
Secondo
;
FANCHINI, ERICA;GIACHERO, ANDREA;GOTTI, CLAUDIO;MAINO, MATTEO;PEREGO, DAVIDE LUIGI
Penultimo
;
PESSINA, GIANLUIGI EZIO
Ultimo
2010

Abstract

We present measurements aimed to characterize the Hamamatsu R7600 multi anode Photon Multiplier Tube (PMT), in view of its application for a new generation of Ring Imaging Cherenkov (RICH) detectors at LHCb. Single photon signals were used as tools for characterization. A commercial blue LED slightly forward biased was the main source of photon light. Spectra obtained with this source coincided with those obtained with the Cherenkov light from a PbF 2 crystal and a 22Na gamma source. Dark current and cross-talk performances were measured. PMT response was studied for single photon signals as a function of the dynodes bias level ratio and magnetic field. Results obtained so far showed that the R7600 PMTs are adequate for the LHCb RICH detectors at high luminosity. © 2010 IEEE.
paper
Radiation; Nuclear and High Energy Physics; Radiology, Nuclear Medicine and Imaging
English
2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010
2010
IEEE Nuclear Science Symposium Conference Record
9781424491063
2010
1124
1129
5873942
none
Arnaboldi, C., Calvi, M., Fanchini, E., Giachero, A., Gotti, C., Maino, M., et al. (2010). Characterization of a Hamamatsu R7600 multi-anode photomultiplier tube with single photon signals. In IEEE Nuclear Science Symposium Conference Record (pp.1124-1129). IEEE [10.1109/NSSMIC.2010.5873942].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/65033
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
Social impact