Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
The Alpha Magnetic Spectrometer (AMS) was flown on the space shuttle Discovery during flight STS-91 (June 1998) in a 51.7 deg orbit at altitudes between 320 and 390 km.
A search for antihelium nuclei in the rigidity range 1–140 GV was performed. No antihelium nuclei were detected at any rigidity. An upper limit on the flux ratio of antihelium to helium of < 1.1×10^−6 was obtained.
The high energy proton, electron, positron, helium, antiproton and deuterium spectra were accurately measured.
For each particle and nuclei two distinct spectra were observed: a higher energy spectrum and a substantial second spectrum. Positrons in the second spectrum were found to be much more abundant than electrons.
Tracing particles from the second spectra shows that most of them travel for an extended period of time in the
geomagnetic field, and that the positive particles (p and e+) and negative ones (e−) originate from two complementary geographic regions. The second helium spectrum flux over the energy range 0.1–1.2 GeV/nucleon was measured to be (6.3 ± 0.9) × 10^−3(m^2 s sr)^−1. Over 90 percent of the helium flux was determined to be 3He at the 90% confidence level
Aguilar, M., Alcaraz, J., Allaby, J., Alpat, B., Ambrosi, G., Anderhub, H., et al. (2002). The Alpha Magnetic Spectrometer (AMS) on the International Space Station: Part I – results from the test flight on the space shuttle. PHYSICS REPORTS, 366(6), 331-405 [10.1016/S0370-1573(02)00013-3].
The Alpha Magnetic Spectrometer (AMS) on the International Space Station: Part I – results from the test flight on the space shuttle
The Alpha Magnetic Spectrometer (AMS) was flown on the space shuttle Discovery during flight STS-91 (June 1998) in a 51.7 deg orbit at altitudes between 320 and 390 km.
A search for antihelium nuclei in the rigidity range 1–140 GV was performed. No antihelium nuclei were detected at any rigidity. An upper limit on the flux ratio of antihelium to helium of < 1.1×10^−6 was obtained.
The high energy proton, electron, positron, helium, antiproton and deuterium spectra were accurately measured.
For each particle and nuclei two distinct spectra were observed: a higher energy spectrum and a substantial second spectrum. Positrons in the second spectrum were found to be much more abundant than electrons.
Tracing particles from the second spectra shows that most of them travel for an extended period of time in the
geomagnetic field, and that the positive particles (p and e+) and negative ones (e−) originate from two complementary geographic regions. The second helium spectrum flux over the energy range 0.1–1.2 GeV/nucleon was measured to be (6.3 ± 0.9) × 10^−3(m^2 s sr)^−1. Over 90 percent of the helium flux was determined to be 3He at the 90% confidence level
Aguilar, M., Alcaraz, J., Allaby, J., Alpat, B., Ambrosi, G., Anderhub, H., et al. (2002). The Alpha Magnetic Spectrometer (AMS) on the International Space Station: Part I – results from the test flight on the space shuttle. PHYSICS REPORTS, 366(6), 331-405 [10.1016/S0370-1573(02)00013-3].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/6186
Citazioni
487
396
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.