Microsampling, especially dried blood spots (DBS), emerged in recent years as a viable alternative to conventional blood collection since it is rapid, simple, minimally invasive, and has user-friendly characteristics. Moreover, DBS are able to avoid analyte degradation thanks to their great stability. Due to their versatility, clinical applications with DBS have increased, including mass spectrometry-based metabolomics and lipidomics studies. In this work, we evaluated and optimized extraction protocols testing five different extraction solutions to perform metabolomics and lipidomics studies on the same spot considering three commercially available microsampling devices, Capitainer, Whatman, and Telimmune. Parallelly, we also evaluated the short-term stability of the three devices at room temperature for up to 5 days. Our results showed that pure methanol was the best compromise to simultaneously extract from the same spot both the lipidome and polar metabolome. However, we also propose a two-step protocol combining methanol and water extraction that improves polar metabolite extraction and shows improved reproducibility in Capitainer and Whatman. Short-term stability results highlighted that both polar metabolites and lipids were stable for up to 6 days using the Capitainer device, while with Whatman and Telimmune, some significant variations were observed after 3 days for some classes of metabolites/lipids, suggesting the need for cold-chain storage when working with these devices.

Bossi, E., Serrao, S., Reveglia, P., Ferrara, A., Nobile, M., Limo, E., et al. (2025). Pre-analytic assessment of dried blood and dried plasma spots: integration in mass spectrometry–based metabolomics and lipidomics workflow. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 417(9), 1791-1805 [10.1007/s00216-025-05760-z].

Pre-analytic assessment of dried blood and dried plasma spots: integration in mass spectrometry–based metabolomics and lipidomics workflow

Bossi E.;Serrao S.;Paglia G.
2025

Abstract

Microsampling, especially dried blood spots (DBS), emerged in recent years as a viable alternative to conventional blood collection since it is rapid, simple, minimally invasive, and has user-friendly characteristics. Moreover, DBS are able to avoid analyte degradation thanks to their great stability. Due to their versatility, clinical applications with DBS have increased, including mass spectrometry-based metabolomics and lipidomics studies. In this work, we evaluated and optimized extraction protocols testing five different extraction solutions to perform metabolomics and lipidomics studies on the same spot considering three commercially available microsampling devices, Capitainer, Whatman, and Telimmune. Parallelly, we also evaluated the short-term stability of the three devices at room temperature for up to 5 days. Our results showed that pure methanol was the best compromise to simultaneously extract from the same spot both the lipidome and polar metabolome. However, we also propose a two-step protocol combining methanol and water extraction that improves polar metabolite extraction and shows improved reproducibility in Capitainer and Whatman. Short-term stability results highlighted that both polar metabolites and lipids were stable for up to 6 days using the Capitainer device, while with Whatman and Telimmune, some significant variations were observed after 3 days for some classes of metabolites/lipids, suggesting the need for cold-chain storage when working with these devices.
Articolo in rivista - Articolo scientifico
Dried blood spots; Lipidomics; Metabolomics; Method optimization; Microsampling;
English
5-feb-2025
2025
417
9
1791
1805
open
Bossi, E., Serrao, S., Reveglia, P., Ferrara, A., Nobile, M., Limo, E., et al. (2025). Pre-analytic assessment of dried blood and dried plasma spots: integration in mass spectrometry–based metabolomics and lipidomics workflow. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 417(9), 1791-1805 [10.1007/s00216-025-05760-z].
File in questo prodotto:
File Dimensione Formato  
Bossi-2025-Analytical and Bioanalytical Chemistry-VoR.pdf

accesso aperto

Descrizione: This article is licensed under a Creative Commons Attribution 4.0 International License To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 5.02 MB
Formato Adobe PDF
5.02 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/548302
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
Social impact