The Silicon Carbide (SiC) Solid State Detector (SSD) is an interesting alternative to diamond detector for fast neutron detection and spectroscopy. Despite this, and unlike diamonds, SiC was never installed on a Tokamak and, thus, was never characterized on a fusion plasma emission. This work aims to predict the response of a SiC when exposed to the neutron spectrum of future Tokamak devices. This is achieved by combining the neutron spectra measured by diamonds during the DTE2 JET campaign with the experimental characterization of SiC at various neutron energies on spallation and DT sources performed in the past through the means of a Geant4 simulation. The SiC response to an ideal thermal plasma and to a neutron and gamma mixed fields are also produced.

Kushoro, M., Colombi, S., Croci, G., Dal Molin, A., Gallo, E., Nocente, M., et al. (2025). SiC detector response to tokamak neutron spectra mock-up validated on experimental results. FUSION ENGINEERING AND DESIGN, 214(May 2025) [10.1016/j.fusengdes.2025.114875].

SiC detector response to tokamak neutron spectra mock-up validated on experimental results

Kushoro M. H.;Colombi S.;Croci G.;Dal Molin A.;Nocente M.;Putignano O.;Rebai M.;Rigamonti D.;Tardocchi M.;Gorini G.
2025

Abstract

The Silicon Carbide (SiC) Solid State Detector (SSD) is an interesting alternative to diamond detector for fast neutron detection and spectroscopy. Despite this, and unlike diamonds, SiC was never installed on a Tokamak and, thus, was never characterized on a fusion plasma emission. This work aims to predict the response of a SiC when exposed to the neutron spectrum of future Tokamak devices. This is achieved by combining the neutron spectra measured by diamonds during the DTE2 JET campaign with the experimental characterization of SiC at various neutron energies on spallation and DT sources performed in the past through the means of a Geant4 simulation. The SiC response to an ideal thermal plasma and to a neutron and gamma mixed fields are also produced.
Articolo in rivista - Articolo scientifico
Fusion Plasma; Neutron detector; Silicon carbide; Tokamak;
English
19-feb-2025
2025
214
May 2025
114875
none
Kushoro, M., Colombi, S., Croci, G., Dal Molin, A., Gallo, E., Nocente, M., et al. (2025). SiC detector response to tokamak neutron spectra mock-up validated on experimental results. FUSION ENGINEERING AND DESIGN, 214(May 2025) [10.1016/j.fusengdes.2025.114875].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/548161
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
Social impact