OBJECTIVES: Memo 4D is a semi-rigid ring with an exclusive saddle shape and progressive increased anteroposterior diameter. This preliminary analysis reports 30-day clinical and haemodynamic outcomes of the MANTRA Memo 4D sub-study. METHODS: MANTRA is an 'umbrella' prospective, multicentre, worldwide post-market study to collect real-life safety and performance data on the Corcym devices. Clinical and echocardiographic outcomes were gathered preoperatively, at discharge and each follow-up. KCCQ-12 questionnaires were collected preoperatively and at 30 days. Echocardiographic studies were performed per a predefined protocol and assessed by an independent core laboratory. RESULTS: In total, 166 patients (52, 31.3% female, mean age 60.7 ± 11.4 years) underwent mitral valve repair with Memo 4D in 17 international institutions between July 2021 and June 2023 (enrolment is still ongoing). Primary was the most common aetiology (157, 94.6%), of which 33 cases of Barlow's disease (19.9%); secondary mitral regurgitation was present in six cases (3.6%). Thirty-day mortality was 0.6% (1). One stroke event (0.6%), one acute kidney failure (0.6%), one myocardial infarction (0.6%) and two reoperations within 30 days were reported. Surgery marked improvement in the patient's NYHA class associated with a significant increase in KCCQ-12 summary score, from 69.1 (SD = 23.7) preoperatively to 83.9 (SD = 15.7) at 30 days. End-diastolic left ventricular diameters decreased from 55.19 (SD = 7.10) preoperatively to 52.70 (SD = 3.76) mm at 30 days, and left atrial volume decreased from 125.79 (SD = 46.33) preoperatively to 91.51 (SD = 37.20) ml at 30 days. Mitral regurgitation significantly reduced after the operation and up to 30-day follow-up. CONCLUSIONS: Mitral valve repair with Memo 4D is associated with good clinical and haemodynamic outcomes in the early period.
Dzemali, O., Rodriguez Cetina Biefer, H., Di Eusanio, M., Fabre, O., Troise, G., Bonaros, N., et al. (2025). Mitral valve repair with the semi-rigid Memo 4D annuloplasty ring: Early clinical and echocardiographic outcomes from the MANTRA study. INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY, 40(1) [10.1093/icvts/ivae208].
Mitral valve repair with the semi-rigid Memo 4D annuloplasty ring: Early clinical and echocardiographic outcomes from the MANTRA study
Badano L.;
2025
Abstract
OBJECTIVES: Memo 4D is a semi-rigid ring with an exclusive saddle shape and progressive increased anteroposterior diameter. This preliminary analysis reports 30-day clinical and haemodynamic outcomes of the MANTRA Memo 4D sub-study. METHODS: MANTRA is an 'umbrella' prospective, multicentre, worldwide post-market study to collect real-life safety and performance data on the Corcym devices. Clinical and echocardiographic outcomes were gathered preoperatively, at discharge and each follow-up. KCCQ-12 questionnaires were collected preoperatively and at 30 days. Echocardiographic studies were performed per a predefined protocol and assessed by an independent core laboratory. RESULTS: In total, 166 patients (52, 31.3% female, mean age 60.7 ± 11.4 years) underwent mitral valve repair with Memo 4D in 17 international institutions between July 2021 and June 2023 (enrolment is still ongoing). Primary was the most common aetiology (157, 94.6%), of which 33 cases of Barlow's disease (19.9%); secondary mitral regurgitation was present in six cases (3.6%). Thirty-day mortality was 0.6% (1). One stroke event (0.6%), one acute kidney failure (0.6%), one myocardial infarction (0.6%) and two reoperations within 30 days were reported. Surgery marked improvement in the patient's NYHA class associated with a significant increase in KCCQ-12 summary score, from 69.1 (SD = 23.7) preoperatively to 83.9 (SD = 15.7) at 30 days. End-diastolic left ventricular diameters decreased from 55.19 (SD = 7.10) preoperatively to 52.70 (SD = 3.76) mm at 30 days, and left atrial volume decreased from 125.79 (SD = 46.33) preoperatively to 91.51 (SD = 37.20) ml at 30 days. Mitral regurgitation significantly reduced after the operation and up to 30-day follow-up. CONCLUSIONS: Mitral valve repair with Memo 4D is associated with good clinical and haemodynamic outcomes in the early period.File | Dimensione | Formato | |
---|---|---|---|
Dzemali-2025-Interdisciplinary Cardiovascular and Thoracic Surgery-VoR.pdf
accesso aperto
Descrizione: This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/)
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Licenza:
Creative Commons
Dimensione
1.09 MB
Formato
Adobe PDF
|
1.09 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.