Background: Previous studies have demonstrated that microvolt T-wave alternans (MTWA) testing is a robust predictor of ventricular tachyarrhythmias and sudden cardiac death (SCD) in at-risk patients. However, recent studies have suggested that MTWA testing is not as good a predictor of " appropriate" implantable cardioverter-defibrillator (ICD) therapy as it is a predictor of SCD in patients without ICDs. Objective: To evaluate the utility of MTWA testing for SCD risk stratification in patients without ICDs. Methods: Patient-level data were obtained from 5 prospective studies of MTWA testing in patients with no history of ventricular arrhythmia or SCD. In these studies, ICDs were implanted in only a minority of patients and patients with ICDs were excluded from the analysis. We conducted a pooled analysis and examined the 2-year risk for SCD based on the MTWA test result. Results: The pooled cohort included 2883 patients. MTWA testing was positive in 856 (30%), negative in 1627 (56%), and indeterminate in 400 (14%) patients. Among patients with a left ventricular ejection fraction (LVEF) of ≤35%, annual SCD event rates were 4.0%, 0.9%, and 4.6% among groups with MTWA positive, negative, and indeterminate test results. The SCD rate was significantly lower among patients with a negative MTWA test result than in patients with either positive or indeterminate MTWA test results (P <.001 for both comparisons). In patients with an LVEF of >35%, annual SCD event rates were 3.0%, 0.3%, and 0.3% among the groups with MTWA positive, negative, and indeterminate test results. The SCD rate associated with a positive MTWA test result was significantly higher than that associated with either negative (P <.001) or indeterminate MTWA test results (P =.003). Conclusions: In patients without ICDs, MTWA testing is a powerful predictor of SCD. Among patients with an LVEF of ≤35%, a negative MTWA test result is associated with a low risk for SCD. Conversely, among patients with an LVEF of >35%, a positive MTWA test result identifies patients at significantly heightened SCD risk. These findings may have important implications for refining primary prevention ICD treatment algorithms.

Merchant, F., Ikeda, T., Pedretti, R., Salerno-Uriarte, J., Chow, T., Chan, P., et al. (2012). Clinical utility of microvolt T-wave alternans testing in identifying patients at high or low risk of sudden cardiac death. HEART RHYTHM, 9(8), 1256-1264 [10.1016/j.hrthm.2012.03.014].

Clinical utility of microvolt T-wave alternans testing in identifying patients at high or low risk of sudden cardiac death

Pedretti R;
2012

Abstract

Background: Previous studies have demonstrated that microvolt T-wave alternans (MTWA) testing is a robust predictor of ventricular tachyarrhythmias and sudden cardiac death (SCD) in at-risk patients. However, recent studies have suggested that MTWA testing is not as good a predictor of " appropriate" implantable cardioverter-defibrillator (ICD) therapy as it is a predictor of SCD in patients without ICDs. Objective: To evaluate the utility of MTWA testing for SCD risk stratification in patients without ICDs. Methods: Patient-level data were obtained from 5 prospective studies of MTWA testing in patients with no history of ventricular arrhythmia or SCD. In these studies, ICDs were implanted in only a minority of patients and patients with ICDs were excluded from the analysis. We conducted a pooled analysis and examined the 2-year risk for SCD based on the MTWA test result. Results: The pooled cohort included 2883 patients. MTWA testing was positive in 856 (30%), negative in 1627 (56%), and indeterminate in 400 (14%) patients. Among patients with a left ventricular ejection fraction (LVEF) of ≤35%, annual SCD event rates were 4.0%, 0.9%, and 4.6% among groups with MTWA positive, negative, and indeterminate test results. The SCD rate was significantly lower among patients with a negative MTWA test result than in patients with either positive or indeterminate MTWA test results (P <.001 for both comparisons). In patients with an LVEF of >35%, annual SCD event rates were 3.0%, 0.3%, and 0.3% among the groups with MTWA positive, negative, and indeterminate test results. The SCD rate associated with a positive MTWA test result was significantly higher than that associated with either negative (P <.001) or indeterminate MTWA test results (P =.003). Conclusions: In patients without ICDs, MTWA testing is a powerful predictor of SCD. Among patients with an LVEF of ≤35%, a negative MTWA test result is associated with a low risk for SCD. Conversely, among patients with an LVEF of >35%, a positive MTWA test result identifies patients at significantly heightened SCD risk. These findings may have important implications for refining primary prevention ICD treatment algorithms.
Articolo in rivista - Articolo scientifico
Arrhythmia; heart failure; ICD; Risk stratification; Sudden cardiac death; T-wave alternans;
English
2012
9
8
1256
1264
open
Merchant, F., Ikeda, T., Pedretti, R., Salerno-Uriarte, J., Chow, T., Chan, P., et al. (2012). Clinical utility of microvolt T-wave alternans testing in identifying patients at high or low risk of sudden cardiac death. HEART RHYTHM, 9(8), 1256-1264 [10.1016/j.hrthm.2012.03.014].
File in questo prodotto:
File Dimensione Formato  
Merchant-2012-Heart Rhythm-preprint.pdf

accesso aperto

Tipologia di allegato: Submitted Version (Pre-print)
Licenza: Altro
Dimensione 773.54 kB
Formato Adobe PDF
773.54 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/525667
Citazioni
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 42
Social impact