Purpose: The novel coronavirus disease (COVID-19) has revived the debate on the optimal tidal volume during acute respiratory distress syndrome (ARDS). Some experts recommend 6 mL/kg of predicted body weight (PBW) for all patients, while others suggest 7–9 mL/kg PBW for those with compliance >50 mL/cmH2O. We investigated whether a tidal volume ≥ 7 ml/kg PBW may be safe in COVID-19 patients, particularly those with compliance >50 mL/cmH2O. Materials and methods: This secondary analysis of a multicenter study compares the Intensive Care Unit (ICU) mortality among 600 patients ventilated with <7 or ≥ 7 mL/kg PBW. Compliance was categorized as <40, 40–50, or > 50 mL/cmH2O. Results: 346 patients were ventilated with <7 (6.2 ± 0.5) mL/kg PBW and 254 with ≥7 (7.9 ± 0.9) mL/kg PBW. ICU mortality was 33 % and 29 % in the two groups (p = 0.272). At multivariable regression analysis, tidal volume ≥ 7 mL/kg PBW was associated with lower ICU mortality in the overall population (odds ratio: 0.62 [95 %-confidence interval: 0.40–0.95]) and in each compliance category. Conclusions: A tidal volume ≥ 7 (up to 9) mL/kg PBW was associated with lower ICU mortality in these COVID-19 patients, including those with compliance <40 mL/cmH2O. This finding should be interpreted cautiously due to the retrospective study design. Trial registration: ClinicalTrails.gov NCT04388670.

Protti, A., Madotto, F., Florio, G., Bove, T., Carlesso, E., Casella, G., et al. (2025). A tidal volume of 7 mL/kg PBW or higher may be safe for COVID-19 patients. JOURNAL OF CRITICAL CARE, 85(February 2025) [10.1016/j.jcrc.2024.154921].

A tidal volume of 7 mL/kg PBW or higher may be safe for COVID-19 patients

Madotto F.;Casella G.;Foti G.;Langer T.;Rezoagli E.;Zanella A.;
2025

Abstract

Purpose: The novel coronavirus disease (COVID-19) has revived the debate on the optimal tidal volume during acute respiratory distress syndrome (ARDS). Some experts recommend 6 mL/kg of predicted body weight (PBW) for all patients, while others suggest 7–9 mL/kg PBW for those with compliance >50 mL/cmH2O. We investigated whether a tidal volume ≥ 7 ml/kg PBW may be safe in COVID-19 patients, particularly those with compliance >50 mL/cmH2O. Materials and methods: This secondary analysis of a multicenter study compares the Intensive Care Unit (ICU) mortality among 600 patients ventilated with <7 or ≥ 7 mL/kg PBW. Compliance was categorized as <40, 40–50, or > 50 mL/cmH2O. Results: 346 patients were ventilated with <7 (6.2 ± 0.5) mL/kg PBW and 254 with ≥7 (7.9 ± 0.9) mL/kg PBW. ICU mortality was 33 % and 29 % in the two groups (p = 0.272). At multivariable regression analysis, tidal volume ≥ 7 mL/kg PBW was associated with lower ICU mortality in the overall population (odds ratio: 0.62 [95 %-confidence interval: 0.40–0.95]) and in each compliance category. Conclusions: A tidal volume ≥ 7 (up to 9) mL/kg PBW was associated with lower ICU mortality in these COVID-19 patients, including those with compliance <40 mL/cmH2O. This finding should be interpreted cautiously due to the retrospective study design. Trial registration: ClinicalTrails.gov NCT04388670.
Articolo in rivista - Articolo scientifico
Acute respiratory distress syndrome (ARDS); Coronavirus disease 2019 (COVID-19); Driving pressure; Lung protective ventilation; Mechanical ventilation; Tidal volume
English
25-set-2024
2025
85
February 2025
154921
none
Protti, A., Madotto, F., Florio, G., Bove, T., Carlesso, E., Casella, G., et al. (2025). A tidal volume of 7 mL/kg PBW or higher may be safe for COVID-19 patients. JOURNAL OF CRITICAL CARE, 85(February 2025) [10.1016/j.jcrc.2024.154921].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/524526
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
Social impact