BACKGROUND: Clinical evaluation of central venous pressure is difficult, depends on experience, and is often inaccurate in patients with chronic advanced heart failure. We assessed the ultrasound-assessed internal jugular vein (JV) distensibility by ultrasound as a noninvasive tool to identify patients with normal right atrial pressure (RAP ≤7 mm Hg) in this population. METHODS: We measured JV distensibility as the Valsalva-to-rest ratio of the vein diameter in a calibration cohort (N=100) and a validation cohort (N=101) of consecutive patients with chronic heart failure with reduced ejection fraction who underwent pulmonary artery catheterization for advanced heart failure therapies workup. RESULTS: A JV distensibility threshold of 1.6 was identified as the most accurate to discriminate between patients with RAP ≤7 versus >7 mm Hg (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.64-0.84]) and confirmed in the validation cohort (receiver operating characteristic, 0.82 [95% CI, 0.73-0.92]). A JV distensibility ratio >1.6 had predictive positive values of 0.86 and 0.94, respectively, to identify patients with RAP ≤7 mm Hg in the calibration and validation cohorts. Compared with patients from the calibration cohort with a high JV distensibility ratio (>1.6; n=42; median RAP, 4 mm Hg; pulmonary capillary wedge pressure, 11 mm Hg), those with a low JV distensibility ratio (≤1.6; n=58; median RAP, 8 mm Hg; pulmonary capillary wedge pressure, 22 mm Hg; P<0.0001 for both) were more likely to die or undergo a left ventricular assist device implant or heart transplantation (event rate at 2 years: 42.7% versus 18.2%; log-rank P=0.034). CONCLUSIONS: Ultrasound-assessed JV distensibility identifies patients with chronic advanced heart failure with normal RAP and better outcomes.

Ammirati, E., Marchetti, D., Colombo, G., Pellicori, P., Gentile, P., D'Angelo, L., et al. (2024). Estimation of Right Atrial Pressure by Ultrasound-Assessed Jugular Vein Distensibility in Patients With Heart Failure. CIRCULATION. HEART FAILURE, 17(2) [10.1161/CIRCHEARTFAILURE.123.010973].

Estimation of Right Atrial Pressure by Ultrasound-Assessed Jugular Vein Distensibility in Patients With Heart Failure

Verde A.;Occhi L.;Bernasconi D. P.;Moreo A.;Oliva F.;
2024

Abstract

BACKGROUND: Clinical evaluation of central venous pressure is difficult, depends on experience, and is often inaccurate in patients with chronic advanced heart failure. We assessed the ultrasound-assessed internal jugular vein (JV) distensibility by ultrasound as a noninvasive tool to identify patients with normal right atrial pressure (RAP ≤7 mm Hg) in this population. METHODS: We measured JV distensibility as the Valsalva-to-rest ratio of the vein diameter in a calibration cohort (N=100) and a validation cohort (N=101) of consecutive patients with chronic heart failure with reduced ejection fraction who underwent pulmonary artery catheterization for advanced heart failure therapies workup. RESULTS: A JV distensibility threshold of 1.6 was identified as the most accurate to discriminate between patients with RAP ≤7 versus >7 mm Hg (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.64-0.84]) and confirmed in the validation cohort (receiver operating characteristic, 0.82 [95% CI, 0.73-0.92]). A JV distensibility ratio >1.6 had predictive positive values of 0.86 and 0.94, respectively, to identify patients with RAP ≤7 mm Hg in the calibration and validation cohorts. Compared with patients from the calibration cohort with a high JV distensibility ratio (>1.6; n=42; median RAP, 4 mm Hg; pulmonary capillary wedge pressure, 11 mm Hg), those with a low JV distensibility ratio (≤1.6; n=58; median RAP, 8 mm Hg; pulmonary capillary wedge pressure, 22 mm Hg; P<0.0001 for both) were more likely to die or undergo a left ventricular assist device implant or heart transplantation (event rate at 2 years: 42.7% versus 18.2%; log-rank P=0.034). CONCLUSIONS: Ultrasound-assessed JV distensibility identifies patients with chronic advanced heart failure with normal RAP and better outcomes.
Articolo in rivista - Articolo scientifico
atrial pressure; congestion; heart failure; hemodynamics; pulmonary artery; ultrasound;
English
1-feb-2024
2024
17
2
E010973
none
Ammirati, E., Marchetti, D., Colombo, G., Pellicori, P., Gentile, P., D'Angelo, L., et al. (2024). Estimation of Right Atrial Pressure by Ultrasound-Assessed Jugular Vein Distensibility in Patients With Heart Failure. CIRCULATION. HEART FAILURE, 17(2) [10.1161/CIRCHEARTFAILURE.123.010973].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/521883
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
Social impact