As one of the main detectors for monitoring neutron flux rate in a nuclear reactor, the fission chamber (FC) suffers from issues such as low sensitivity, limited counting rate dynamic range, and system mode switching is cumbersome. This study utilizes the advantages of gas electron multipliers (GEM), which are easy to fabricate in large areas and have high counting rates, to design a novel fission chamber. By conducting Monte Carlo simulations on parameters such as the thickness of the 235U coating, the drift distance, and the operating electric field strength, a wide-range fission chamber design that combines high sensitivity and a counting rate range based on GEM has been obtained. The simulation results demonstrated that using a GEM detector to build a fission chamber can significantly improve sensitivity and extend the counting rate range. Subsequently we built a proof-of-concept GEM-based fission chamber and tested it with a 55Fe low-energy X-ray source and an Am-Be neutron source. The results showed that the proof-of-concept detector had a good signal-to-noise ratio and energy linearity, as well as clear discrimination between alpha background and neutron pulse amplitudes.

Ye, Y., Zhao, X., Wang, X., Feng, S., Wei, Q., Tian, J., et al. (2024). Design and characterization of a new high-count wide-range fission chamber based on GEM. JOURNAL OF INSTRUMENTATION, 19(5) [10.1088/1748-0221/19/05/P05069].

Design and characterization of a new high-count wide-range fission chamber based on GEM

Feng S.;
2024

Abstract

As one of the main detectors for monitoring neutron flux rate in a nuclear reactor, the fission chamber (FC) suffers from issues such as low sensitivity, limited counting rate dynamic range, and system mode switching is cumbersome. This study utilizes the advantages of gas electron multipliers (GEM), which are easy to fabricate in large areas and have high counting rates, to design a novel fission chamber. By conducting Monte Carlo simulations on parameters such as the thickness of the 235U coating, the drift distance, and the operating electric field strength, a wide-range fission chamber design that combines high sensitivity and a counting rate range based on GEM has been obtained. The simulation results demonstrated that using a GEM detector to build a fission chamber can significantly improve sensitivity and extend the counting rate range. Subsequently we built a proof-of-concept GEM-based fission chamber and tested it with a 55Fe low-energy X-ray source and an Am-Be neutron source. The results showed that the proof-of-concept detector had a good signal-to-noise ratio and energy linearity, as well as clear discrimination between alpha background and neutron pulse amplitudes.
Articolo in rivista - Articolo scientifico
Detector modelling and simulations II (electric fields, charge transport, multiplication and induction, pulse formation, electron emission, etc); Electron multipliers (gas); Gaseous detectors;
English
2024
19
5
P05069
reserved
Ye, Y., Zhao, X., Wang, X., Feng, S., Wei, Q., Tian, J., et al. (2024). Design and characterization of a new high-count wide-range fission chamber based on GEM. JOURNAL OF INSTRUMENTATION, 19(5) [10.1088/1748-0221/19/05/P05069].
File in questo prodotto:
File Dimensione Formato  
Ye-2024-Journal of Instrumentation-VoR.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Tutti i diritti riservati
Dimensione 3.4 MB
Formato Adobe PDF
3.4 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/513662
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
Social impact