The FIssion Neutron spectrum Detector Array (FINDA) has been designed for measurement of prompt fission neutron spectrum on the Back-n beam line at the China Spallation Neutron Source (CSNS). In order to test the neutron-γ discrimination performance of the EJ301 scintillator that will be used as a detector unit in the FINDA, a comparative study using three conventional digital pulse shape discrimination (PSD) methods has been carried out. An Am–Be source has been used to generate the mixed neutron-γ radiation and the waveform data has been obtained with a fast digitizer. Pulse interpolation, baseline restoration and pulses pile-up rejection have been applied for digital pulse processing. Charge comparison (CC) method and simplified charge comparison(SCC) method show a better capability of neutron-γ discrimination than rise time comparison(RTC) method over the entire energy range. Rise time comparison method needs a very fast digitizer or pulse interpolation to improve the PSD ability. The analysis of neutron-γ discrimination performance of the EJ301 scintillator provides a strong technical support for fast neutron measurement using the FINDA at CSNS.

Zhao, D., Feng, S., Hu, C., Zhang, Z., Wang, H., Zhu, K., et al. (2022). Characterization of the neutron/γ-ray discrimination performance in an EJ-301 liquid scintillator for application to prompt fission neutron spectrum measurements at CSNS. RADIATION MEASUREMENTS, 151 [10.1016/j.radmeas.2022.106703].

Characterization of the neutron/γ-ray discrimination performance in an EJ-301 liquid scintillator for application to prompt fission neutron spectrum measurements at CSNS

Feng S.;
2022

Abstract

The FIssion Neutron spectrum Detector Array (FINDA) has been designed for measurement of prompt fission neutron spectrum on the Back-n beam line at the China Spallation Neutron Source (CSNS). In order to test the neutron-γ discrimination performance of the EJ301 scintillator that will be used as a detector unit in the FINDA, a comparative study using three conventional digital pulse shape discrimination (PSD) methods has been carried out. An Am–Be source has been used to generate the mixed neutron-γ radiation and the waveform data has been obtained with a fast digitizer. Pulse interpolation, baseline restoration and pulses pile-up rejection have been applied for digital pulse processing. Charge comparison (CC) method and simplified charge comparison(SCC) method show a better capability of neutron-γ discrimination than rise time comparison(RTC) method over the entire energy range. Rise time comparison method needs a very fast digitizer or pulse interpolation to improve the PSD ability. The analysis of neutron-γ discrimination performance of the EJ301 scintillator provides a strong technical support for fast neutron measurement using the FINDA at CSNS.
Articolo in rivista - Articolo scientifico
EJ301 scintillator; Fast digitizer; Pulse interpolation; Pulse shape discrimination (PSD);
English
22-gen-2022
2022
151
106703
reserved
Zhao, D., Feng, S., Hu, C., Zhang, Z., Wang, H., Zhu, K., et al. (2022). Characterization of the neutron/γ-ray discrimination performance in an EJ-301 liquid scintillator for application to prompt fission neutron spectrum measurements at CSNS. RADIATION MEASUREMENTS, 151 [10.1016/j.radmeas.2022.106703].
File in questo prodotto:
File Dimensione Formato  
Zhao-2022-Radiation Measurements-VoR.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Tutti i diritti riservati
Dimensione 1.78 MB
Formato Adobe PDF
1.78 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/513621
Citazioni
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 8
Social impact