Purpose: Airway closure is a interruption of communication between larger and smaller airways. The presence of airway closure during mechanical ventilation may lead to the overestimation of driving pressure (DP), introducing errors in the assessment of respiratory mechanics and in positive end-expiratory pressure (PEEP) setting on the ventilator. Patients with severe acute respiratory distress syndrome (ARDS) may exhibit the airway closure phenomenon, which can be easily diagnosed with a low-flow inflation. Prone positioning is a therapeutic manoeuver proven to reduce mortality in ARDS patients, and has been widely implemented also in patients requiring veno-venous extracorporeal membrane oxygenation (V-V ECMO). To date, the impact of prone positioning on changes in airway closure has not been described. Methods: We present an image analysis of the pressure waveform during volume-controlled ventilation and low-flow inflations before and after prone positioning in an ARDS patient on VV ECMO. Results: A high airway opening pressure level (23 cmH2O) was detected in the supine position during tidal ventilation. Airway closure was confirmed by using a low-flow inflation. Prone positioning significantly attenuated airway closure, with the airway opening pressure decreasing to 13 cmH2O. After re-supination, airway closure was lower as compared with supine position at baseline (17 cmH2O). Conclusion: Prone positioning reduced airway closure in an ARDS patient on VV ECMO support.

Giani, M., Restivo, A., Raimondi Cominesi, D., Fracchia, R., Pozzi, M., Del Sorbo, L., et al. (2024). Prone-position decreases airway closure in a patient with ARDS undergoing venovenous extracorporeal membrane oxygenation. JOURNAL OF CLINICAL MONITORING AND COMPUTING [10.1007/s10877-024-01182-x].

Prone-position decreases airway closure in a patient with ARDS undergoing venovenous extracorporeal membrane oxygenation

Giani, Marco;Restivo, Andrea;Raimondi Cominesi, Davide;Fracchia, Rosa;Pozzi, Matteo;Foti, Giuseppe;Rezoagli, Emanuele
2024

Abstract

Purpose: Airway closure is a interruption of communication between larger and smaller airways. The presence of airway closure during mechanical ventilation may lead to the overestimation of driving pressure (DP), introducing errors in the assessment of respiratory mechanics and in positive end-expiratory pressure (PEEP) setting on the ventilator. Patients with severe acute respiratory distress syndrome (ARDS) may exhibit the airway closure phenomenon, which can be easily diagnosed with a low-flow inflation. Prone positioning is a therapeutic manoeuver proven to reduce mortality in ARDS patients, and has been widely implemented also in patients requiring veno-venous extracorporeal membrane oxygenation (V-V ECMO). To date, the impact of prone positioning on changes in airway closure has not been described. Methods: We present an image analysis of the pressure waveform during volume-controlled ventilation and low-flow inflations before and after prone positioning in an ARDS patient on VV ECMO. Results: A high airway opening pressure level (23 cmH2O) was detected in the supine position during tidal ventilation. Airway closure was confirmed by using a low-flow inflation. Prone positioning significantly attenuated airway closure, with the airway opening pressure decreasing to 13 cmH2O. After re-supination, airway closure was lower as compared with supine position at baseline (17 cmH2O). Conclusion: Prone positioning reduced airway closure in an ARDS patient on VV ECMO support.
Lettera in rivista
Acute respiratory distress syndrome; Airway closure; Driving pressure; Prone position; Respiratory mechanics; Veno-venous extracorporeal membrane oxygenation
English
2024
reserved
Giani, M., Restivo, A., Raimondi Cominesi, D., Fracchia, R., Pozzi, M., Del Sorbo, L., et al. (2024). Prone-position decreases airway closure in a patient with ARDS undergoing venovenous extracorporeal membrane oxygenation. JOURNAL OF CLINICAL MONITORING AND COMPUTING [10.1007/s10877-024-01182-x].
File in questo prodotto:
File Dimensione Formato  
Giani-2024-J Clin Monit Comput-VoR.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Tutti i diritti riservati
Dimensione 1.27 MB
Formato Adobe PDF
1.27 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/498919
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
Social impact