We evaluated agreement and reliability of tear non-invasive breakup time (NIBUT) performed with different devices and with respect to fluorescein procedure (fBUT). Data were collected on 43 subjects (17 males; age range: 18--29 years). NIBUT was measured in a random order with different devices: EasyTear (ET), Polaris (PO) and Sirius (SI). At the end fBUT was acquired. The whole procedure was repeated (retest) 2 hours after the last measurement. BUT (s) was 12.0±7.6,12.8±6.8,14.8±8.0,8.7±5.2 in the right eye (RE) and 12.0±8.2,14.1±9.8,15.6±7.8,8.6±5.0 in the left eye (LE) with the ET, PO, SI and fBUT, respectively. ANOVA showed a significant difference between measures. All paired comparisons between BUT values were significantly different, except for ET vs. PO (RE) and PO vs. SI (LE). All correlations between NIBUT procedures resulted statistically significant. All procedures showed no difference between test and retest and ICC resulted higher for NIBUT devices with respect to fBUT. In conclusion fBUT was significantly shorter than NIBUTs. Devices cannot be considered interchangeable; however, they showed similar test-retest reliability.

Tavazzi, S., Rizzo, G., Ponzini, E., Zeri, F. (2023). Comparison of tear film stability assessment procedures by non-invasive and fluorescein tear breakup time measurement. Intervento presentato a: 109° Congresso Nazionale della Società Italiana di Fisica, Fisciano, Italia.

Comparison of tear film stability assessment procedures by non-invasive and fluorescein tear breakup time measurement

Tavazzi, S.;Rizzo, GC;Ponzini, E
;
Zeri, F
2023

Abstract

We evaluated agreement and reliability of tear non-invasive breakup time (NIBUT) performed with different devices and with respect to fluorescein procedure (fBUT). Data were collected on 43 subjects (17 males; age range: 18--29 years). NIBUT was measured in a random order with different devices: EasyTear (ET), Polaris (PO) and Sirius (SI). At the end fBUT was acquired. The whole procedure was repeated (retest) 2 hours after the last measurement. BUT (s) was 12.0±7.6,12.8±6.8,14.8±8.0,8.7±5.2 in the right eye (RE) and 12.0±8.2,14.1±9.8,15.6±7.8,8.6±5.0 in the left eye (LE) with the ET, PO, SI and fBUT, respectively. ANOVA showed a significant difference between measures. All paired comparisons between BUT values were significantly different, except for ET vs. PO (RE) and PO vs. SI (LE). All correlations between NIBUT procedures resulted statistically significant. All procedures showed no difference between test and retest and ICC resulted higher for NIBUT devices with respect to fBUT. In conclusion fBUT was significantly shorter than NIBUTs. Devices cannot be considered interchangeable; however, they showed similar test-retest reliability.
relazione (orale)
tear film stability, non-invasive breakup time, fluorescein
English
109° Congresso Nazionale della Società Italiana di Fisica
2023
2023
https://2023.congresso.sif.it/talk/90
none
Tavazzi, S., Rizzo, G., Ponzini, E., Zeri, F. (2023). Comparison of tear film stability assessment procedures by non-invasive and fluorescein tear breakup time measurement. Intervento presentato a: 109° Congresso Nazionale della Società Italiana di Fisica, Fisciano, Italia.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/483779
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
Social impact