Background and Objectives: This study aimed to assess the effectiveness and costs associated with pharmacokinetics-driven (PK) prophylaxis based on the myPKFiT® device in patients affected by hemophilia A (HA) in Italy. Materials and Methods: An observational retrospective study was conducted in three Italian hemophilia centers. All patients with moderate or severe HA, aged ≥ 18 years, capable of having PK estimated using the myPKFiT device, and who had had a clinical visit between 1 November 2019 and 31 March 2022 were included. Differences in clinical, treatment, health resources, and cost data were assessed comparing post-PK prophylaxis with pre-PK. The incremental cost-effectiveness ratio (ICER) was estimated as cost (EUR) per bleed avoided. Results: The study enrolled 13 patients with HA. The mean annual bleeding rate decreased by −1.45 (−63.80%, p = 0.0055) after the use of myPKFiT®. Overall, the consumption of FVIII IU increased by 1.73% during follow-up compared to the period prior the use of the myPKFiT. Prophylaxis based on the myPKFiT resulted in an ICER of EUR 5099.89 per bleed avoided. Conclusions: The results of our study support the idea that the use of PK data in clinical practice can be associated with an improvement in the management of patients, as well as clinical outcomes, with a reasonable increase in costs.
Antonazzo, I., Cortesi, P., Zanon, E., Pasca, S., Morfini, M., Santoro, C., et al. (2024). Personalized Prophylaxis with myPKFiTCE: A Real-World Cost-Effectiveness Analysis in Haemophilia A Patients. MEDICINA, 60(1) [10.3390/medicina60010034].
Personalized Prophylaxis with myPKFiTCE: A Real-World Cost-Effectiveness Analysis in Haemophilia A Patients
Antonazzo I. C.
;Cortesi P. A.;Mantovani L. G.
2024
Abstract
Background and Objectives: This study aimed to assess the effectiveness and costs associated with pharmacokinetics-driven (PK) prophylaxis based on the myPKFiT® device in patients affected by hemophilia A (HA) in Italy. Materials and Methods: An observational retrospective study was conducted in three Italian hemophilia centers. All patients with moderate or severe HA, aged ≥ 18 years, capable of having PK estimated using the myPKFiT device, and who had had a clinical visit between 1 November 2019 and 31 March 2022 were included. Differences in clinical, treatment, health resources, and cost data were assessed comparing post-PK prophylaxis with pre-PK. The incremental cost-effectiveness ratio (ICER) was estimated as cost (EUR) per bleed avoided. Results: The study enrolled 13 patients with HA. The mean annual bleeding rate decreased by −1.45 (−63.80%, p = 0.0055) after the use of myPKFiT®. Overall, the consumption of FVIII IU increased by 1.73% during follow-up compared to the period prior the use of the myPKFiT. Prophylaxis based on the myPKFiT resulted in an ICER of EUR 5099.89 per bleed avoided. Conclusions: The results of our study support the idea that the use of PK data in clinical practice can be associated with an improvement in the management of patients, as well as clinical outcomes, with a reasonable increase in costs.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.