Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay (0νββ) of 100Mo. It uses 20 scintillating 100Mo-enriched Li2MoO4 bolometers instrumented with Ge light detectors to perform active suppression of α backgrounds, drastically reducing the expected background in the 0νββ signal region. As a result, pileup events and small detector instabilities that mimic normal signals become non-negligible potential backgrounds. These types of events can in principle be eliminated based on their signal shapes, which are different from those of regular bolometric pulses. We show that a purely data-driven principal component analysis based approach is able to filter out these anomalous events, without the aid of detector response simulations.
Huang, R., Armengaud, E., Augier, C., Barabash, A., Bellini, F., Benato, G., et al. (2021). Pulse shape discrimination in CUPID-Mo using principal component analysis. JOURNAL OF INSTRUMENTATION, 16(3) [10.1088/1748-0221/16/03/P03032].
Pulse shape discrimination in CUPID-Mo using principal component analysis
Huang R.
;Armengaud E.;Augier C.;Barabash A. S.;Bellini F.;Benato G.;Beno t A.;Beretta M.;Bergé L.;Billard J.;Borovlev Y. A.;Bourgeois C.;Brudanin V. B.;Camus P.;Cardani L.;Casali N.;Cazes A.;Chapellier M.;Charlieux F.;De Combarieu M.;Dafinei I.;Danevich F. A.;De Jesus M.;Dixon T.;Dumoulin L.;Eitel K.;Ferri F.;Fujikawa B. K.;Gascon J.;Gironi L.;Giuliani A.;Grigorieva V. D.;Gros M.;Guerard E.;Helis D. L.;Huang H. Z.;Johnston J.;Juillard A.;Khalife H.;Kleifges M.;Kobychev V. V.;Kolomensky Y. G.;Konovalov S. I.;Loaiza P.;Ma L.;Makarov E. P.;De Marcillac P.;Mariam R.;Marini L.;Marnieros S.;Misiak D.;Navick X. F.;Nones C.;Norman E. B.;Olivieri E.;Ouellet J. L.;Pagnanini L.;Pari P.;Pattavina L.;Paul B.;Pavan M.;Peng H.;Pessina G.;Pirro S.;Poda D. V.;Polischuk O. G.;Previtali E.;Redon T.;Rozov S.;Rusconi C.;Sanglard V.;Scarpaci J. A.;Sch ffner K.;Schmidt B.;Shen Y.;Shlegel V. N.;Siebenborn B.;Singh V.;Tomei C.;Tretyak V. I.;Umatov V. I.;Vagneron L.;Velázquez M.;Weber M.;Welliver B.;Winslow L.;Xue M.;Yakushev E.;Zarytskyy M. M.;Zolotarova A. S.
2021
Abstract
CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay (0νββ) of 100Mo. It uses 20 scintillating 100Mo-enriched Li2MoO4 bolometers instrumented with Ge light detectors to perform active suppression of α backgrounds, drastically reducing the expected background in the 0νββ signal region. As a result, pileup events and small detector instabilities that mimic normal signals become non-negligible potential backgrounds. These types of events can in principle be eliminated based on their signal shapes, which are different from those of regular bolometric pulses. We show that a purely data-driven principal component analysis based approach is able to filter out these anomalous events, without the aid of detector response simulations.
Huang, R., Armengaud, E., Augier, C., Barabash, A., Bellini, F., Benato, G., et al. (2021). Pulse shape discrimination in CUPID-Mo using principal component analysis. JOURNAL OF INSTRUMENTATION, 16(3) [10.1088/1748-0221/16/03/P03032].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/458559
Citazioni
15
14
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.