The translational potential of pre-clinical stroke research depends on the accuracy of experimental modeling. Cerebral perfusion monitoring in animal models of acute ischemic stroke allows to confirm successful arterial occlusion and exclude subarachnoid hemorrhage. Cerebral perfusion monitoring can also be used to study intracranial collateral circulation, which is emerging as a powerful determinant of stroke outcome and a possible therapeutic target. Despite a recognized role of Laser Doppler perfusion monitoring as part of the current guidelines for experimental cerebral ischemia, a number of technical difficulties exist that limit its widespread use. One of the major issues is obtaining a secure and prolonged attachment of a deep-penetration Laser Doppler probe to the animal skull. In this video, we show our optimized system for cerebral perfusion monitoring during transient middle cerebral artery occlusion by intraluminal filament in the rat. We developed in-house a simple method to obtain a custom made holder for twin-fibre (deep-penetration) Laser Doppler probes, which allow multi-site monitoring if needed. A continuous and prolonged monitoring of cerebral perfusion could easily be obtained over the intact skull

Beretta, S., Riva, M., Carone, D., Cuccione, E., Padovano, G., RODRIGUEZ MENENDEZ, V., et al. (2013). Optimized system for cerebral perfusion monitoring in the rat stroke model of intraluminal middle cerebral artery occlusion. JOURNAL OF VISUALIZED EXPERIMENTS, 2013(72) [10.3791/50214].

Optimized system for cerebral perfusion monitoring in the rat stroke model of intraluminal middle cerebral artery occlusion

Beretta, S
;
CARONE, DAVIDE;CUCCIONE, ELISA;RODRIGUEZ MENENDEZ, VIRGINIA;GIUSSANI, CARLO GIORGIO;SGANZERLA, ERIK PIETRO;FERRARESE, CARLO
2013

Abstract

The translational potential of pre-clinical stroke research depends on the accuracy of experimental modeling. Cerebral perfusion monitoring in animal models of acute ischemic stroke allows to confirm successful arterial occlusion and exclude subarachnoid hemorrhage. Cerebral perfusion monitoring can also be used to study intracranial collateral circulation, which is emerging as a powerful determinant of stroke outcome and a possible therapeutic target. Despite a recognized role of Laser Doppler perfusion monitoring as part of the current guidelines for experimental cerebral ischemia, a number of technical difficulties exist that limit its widespread use. One of the major issues is obtaining a secure and prolonged attachment of a deep-penetration Laser Doppler probe to the animal skull. In this video, we show our optimized system for cerebral perfusion monitoring during transient middle cerebral artery occlusion by intraluminal filament in the rat. We developed in-house a simple method to obtain a custom made holder for twin-fibre (deep-penetration) Laser Doppler probes, which allow multi-site monitoring if needed. A continuous and prolonged monitoring of cerebral perfusion could easily be obtained over the intact skull
Articolo in rivista - Articolo scientifico
rat, stroke model, cerebral perfusion
English
2013
2013
72
e50214
reserved
Beretta, S., Riva, M., Carone, D., Cuccione, E., Padovano, G., RODRIGUEZ MENENDEZ, V., et al. (2013). Optimized system for cerebral perfusion monitoring in the rat stroke model of intraluminal middle cerebral artery occlusion. JOURNAL OF VISUALIZED EXPERIMENTS, 2013(72) [10.3791/50214].
File in questo prodotto:
File Dimensione Formato  
Optimized cerebral perfusion monitoring.pdf

Solo gestori archivio

Dimensione 556.3 kB
Formato Adobe PDF
556.3 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/44158
Citazioni
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 5
Social impact