Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
The LHCb collaboration has redesigned its trigger to enable the full offline detector reconstruction to be performed in real time. Together with the real-time alignment and calibration of the detector, and a software infrastructure to make persistent the high-level physics objects produced during real-time processing, this redesign enabled the widespread deployment of real-time analysis during Run 2. We describe the design of the Run 2 trigger and real-time reconstruction, and present data-driven performance measurements for a representative sample of LHCb's physics programme.
Aaij, R., Akar, S., Albrecht, J., Alexander, M., Albero, A., Amerio, S., et al. (2019). Design and performance of the LHCb trigger and full real-time reconstruction in Run 2 of the LHC. JOURNAL OF INSTRUMENTATION, 14(4) [10.1088/1748-0221/14/04/P04013].
Design and performance of the LHCb trigger and full real-time reconstruction in Run 2 of the LHC
Aaij R.;Akar S.;Albrecht J.;Alexander M.;Albero A. A.;Amerio S.;Anderlini L.;D'Argent P.;Baranov A.;Barter W.;Benson S.;Bobulska D.;Boettcher T.;Borghi S.;Bowen E. E.;Brarda L.;Burr C.;Cachemiche J. -P.;Gomez M. C.;Cattaneo M.;Chanal H.;Chapman M.;Chebbi M.;Chefdeville M.;Ciambrone P.;Cogan J.;Chitic S. -G.;Clemencic M.;Closier J.;Couturier B.;Daoudi M.;Bruyn K. D.;Cian M. D.;Deschamps O.;Dettori F.;Dordei F.;Douglas L.;Dreimanis K.;Dufour L.;Dujany G.;Durante P.;Duval P. -Y.;Dziurda A.;Esen S.;Fitzpatrick C.;Fontanna M.;Frank M.;Veghel M. V.;Gaspar C.;Gerstel D.;Ghez P.;Gizdov K.;Gligorov V. V.;Govorkova E.;Cardoso L. A. G.;Grillo L.;Guz I.;Hachon F.;He J.;Hill D.;Hu W.;Hulsbergen W.;Ilten P.;Li Y.;Linn C. P.;Lupton O.;Johnson D.;Jones C. R.;Jost B.;Kenzie M.;Kopecna R.;Koppenburg P.;Kreps M.;Gac R. L.;Lefevre R.;Leroy O.;MacHefert F.;Mancinelli G.;Maddrell-Mander S.;Marchand J. F.;Marconi U.;Benito C. M.;Martinelli M.;Santos D. M.;Matev R.;Michielin E.;Monteil S.;Morris A.;Minard M. -N.;Mohamed H.;Morello M. J.;Naik P.;Neubert S.;Neufeld N.;Niel E.;Pearce A.;Perret P.;Polci F.;Prisciandaro J.;Prouve C.;Navarro A. P.;Pernas M. R.;Raven G.;Rethore F.;Molina V. R.;Robbe P.;Sarpis G.;Sborzacchi F.;Schiller M.;Schwemmer R.;Sciascia B.;Serrano J.;Seyfert P.;Schune M. -H.;Smith M.;Solomin A.;Sokoloff M.;Spradlin P.;Stahl M.;Stahl S.;Storaci B.;Stracka S.;Szymanski M.;Traill M.;Usachov A.;Valat S.;Gomez R. V.;Vesterinen M.;Voneki B.;Wang M.;Weisser C.;Whitehead M.;Williams M.;Winn M.;Witek M.;Xiang Z.;Xu A.;Xu Z.;Yin H.;Zhang Y.;Zhou Y.
2019
Abstract
The LHCb collaboration has redesigned its trigger to enable the full offline detector reconstruction to be performed in real time. Together with the real-time alignment and calibration of the detector, and a software infrastructure to make persistent the high-level physics objects produced during real-time processing, this redesign enabled the widespread deployment of real-time analysis during Run 2. We describe the design of the Run 2 trigger and real-time reconstruction, and present data-driven performance measurements for a representative sample of LHCb's physics programme.
Aaij, R., Akar, S., Albrecht, J., Alexander, M., Albero, A., Amerio, S., et al. (2019). Design and performance of the LHCb trigger and full real-time reconstruction in Run 2 of the LHC. JOURNAL OF INSTRUMENTATION, 14(4) [10.1088/1748-0221/14/04/P04013].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/396961
Citazioni
75
46
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.