The current protocols for biocompatibility assessment of biomaterials, based on histopathology, require the sacrifice of a huge number of laboratory animals with an unsustainable ethical burden and remarkable cost. Intravital microscopy techniques can be used to study implantation outcomes in real time though with limited capabilities of quantification in longitudinal studies, mainly restricted by the light penetration and the spatial resolution in deep tissues. We present the outline and first tests of a novel chip which aims to enable longitudinal studies of the reaction to the biomaterial implant. The chip is composed of a regular reference microstructure fabricated via two-photon polymerization in the SZ2080 resist. The geometrical design and the planar raster spacing largely determine the mechanical and spectroscopic features of the microstructures. The development, in-vitro characterization and in vivo validation of the Microatlas is performed in living chicken embryos by fluorescence microscopy 3 and 4 days after the implant; the quantification of cell infiltration inside the Microatlas demonstrates its potential as novel scaffold for tissue regeneration.
Conci, C., Jacchetti, E., Sironi, L., Gentili, L., Cerullo, G., Martinez, R., et al. (2022). A miniaturized chip for 3D optical imaging of tissue regeneration in vivo. Intervento presentato a: Biomedical Spectroscopy, Microscopy, and Imaging II 2022 - 9 May 2022 through 20 May 2022, Strasbourg, France (Virtual, Online) [10.1117/12.2629824].
A miniaturized chip for 3D optical imaging of tissue regeneration in vivo
Sironi L.;Marini M.;Bouzin M.;Collini M.;D'Alfonso L.;Chirico G.
;
2022
Abstract
The current protocols for biocompatibility assessment of biomaterials, based on histopathology, require the sacrifice of a huge number of laboratory animals with an unsustainable ethical burden and remarkable cost. Intravital microscopy techniques can be used to study implantation outcomes in real time though with limited capabilities of quantification in longitudinal studies, mainly restricted by the light penetration and the spatial resolution in deep tissues. We present the outline and first tests of a novel chip which aims to enable longitudinal studies of the reaction to the biomaterial implant. The chip is composed of a regular reference microstructure fabricated via two-photon polymerization in the SZ2080 resist. The geometrical design and the planar raster spacing largely determine the mechanical and spectroscopic features of the microstructures. The development, in-vitro characterization and in vivo validation of the Microatlas is performed in living chicken embryos by fluorescence microscopy 3 and 4 days after the implant; the quantification of cell infiltration inside the Microatlas demonstrates its potential as novel scaffold for tissue regeneration.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.