In emission tomography the Fisher information matrix is highly non-uniform along the diagonal due to the Poisson nature of photon counting. For this reason, quadratic penalties result in non-uniform spatial resolution, with the poorest resolution in regions with most counts. A strategy had been proposed to spatially modulate the penalty strength to achieve uniform resolution. In recent years, however, regularizations based on the L1 norm have generated much interest for their sparsity inducing proprieties. Nonetheless, we observed that, in emission tomography, if the penalty is not spatially modulated it suffers from the same problem observed in the L2 case. We propose here a spatial modulation factor for L1 penalties. We test this approach in two independent tasks. The first one involves the reconstruction of 2D PET digital phantoms in a sparse wavelet basis. The second task is the reconstruction of the attenuation map from emission data in 3D human studies with two L1 terms. In both tasks the proposed strategy greatly improves image quality and produces images that appear to be of uniform spatial resolution.

Presotto, L., Bettinardi, V. (2019). Spatial Modulation for L1 penalty terms in emission tomography. In 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2019. Institute of Electrical and Electronics Engineers Inc. [10.1109/NSS/MIC42101.2019.9059631].

Spatial Modulation for L1 penalty terms in emission tomography

Presotto L.
;
2019

Abstract

In emission tomography the Fisher information matrix is highly non-uniform along the diagonal due to the Poisson nature of photon counting. For this reason, quadratic penalties result in non-uniform spatial resolution, with the poorest resolution in regions with most counts. A strategy had been proposed to spatially modulate the penalty strength to achieve uniform resolution. In recent years, however, regularizations based on the L1 norm have generated much interest for their sparsity inducing proprieties. Nonetheless, we observed that, in emission tomography, if the penalty is not spatially modulated it suffers from the same problem observed in the L2 case. We propose here a spatial modulation factor for L1 penalties. We test this approach in two independent tasks. The first one involves the reconstruction of 2D PET digital phantoms in a sparse wavelet basis. The second task is the reconstruction of the attenuation map from emission data in 3D human studies with two L1 terms. In both tasks the proposed strategy greatly improves image quality and produces images that appear to be of uniform spatial resolution.
poster + paper
image reconstruction; emission tomography; regularization;
English
2019 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2019 - 26 October 2019 through 2 November 2019
2019
2019 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2019
9781728141640
2019
9059631
none
Presotto, L., Bettinardi, V. (2019). Spatial Modulation for L1 penalty terms in emission tomography. In 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2019. Institute of Electrical and Electronics Engineers Inc. [10.1109/NSS/MIC42101.2019.9059631].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/380391
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
Social impact