Transcatheter aortic valve replacement (TAVR) is an increasingly used alternative to surgical aortic valve replacement in patients with severe aortic stenosis and prohibitive perioperative risk. Several studies have shown an improved clinical outcome and lower rate of complications with TAVR in this patient population. Furthermore, TAVR has shown promising results in patients at elevated risk from surgical aortic valve replacement. Because of the endovascular nature of this technique, comprehensive preprocedural assessment of the aortic root and vascular access path is crucial. Although echocardiography is still commonly performed to assess the aortic root, cross-sectional imaging modalities are increasingly used given their superior results in the diagnostic accuracy of TAVR measurements. In particular, computed tomography (CT) is gaining an increasing role in pre-TAVR imaging because of fast 3-dimensional assessment of aortic root anatomy and improvements in clinical outcome after TAVR when CT is used for pre-TAVR planning. However, different algorithms exist for matching valve size to the aortic root and left ventricular outflow tract, and these measurements may substantially impact valve prosthesis selection and postinterventional complication rates. Cardiac magnetic resonance may play a role especially in post-TAVR assessment, as it provides both anatomic information and blood flow dynamics. This article reviews multimodality imaging approaches to pre-TAVR aortic root size assessment, provides an overview of the impact on post-TAVR complications and clinical outcome, and describes recent techniques to reduce contrast material volume in TAVR assessment with CT.

Wichmann, J., Varga-Szemes, A., Suranyi, P., Bayer RR, 2., Litwin, S., De Cecco, C., et al. (2015). Transcatheter aortic valve replacement imaging techniques for aortic root sizing. JOURNAL OF THORACIC IMAGING, 30(6), 349-358 [10.1097/RTI.0000000000000167].

Transcatheter aortic valve replacement imaging techniques for aortic root sizing

Muscogiuri G;
2015

Abstract

Transcatheter aortic valve replacement (TAVR) is an increasingly used alternative to surgical aortic valve replacement in patients with severe aortic stenosis and prohibitive perioperative risk. Several studies have shown an improved clinical outcome and lower rate of complications with TAVR in this patient population. Furthermore, TAVR has shown promising results in patients at elevated risk from surgical aortic valve replacement. Because of the endovascular nature of this technique, comprehensive preprocedural assessment of the aortic root and vascular access path is crucial. Although echocardiography is still commonly performed to assess the aortic root, cross-sectional imaging modalities are increasingly used given their superior results in the diagnostic accuracy of TAVR measurements. In particular, computed tomography (CT) is gaining an increasing role in pre-TAVR imaging because of fast 3-dimensional assessment of aortic root anatomy and improvements in clinical outcome after TAVR when CT is used for pre-TAVR planning. However, different algorithms exist for matching valve size to the aortic root and left ventricular outflow tract, and these measurements may substantially impact valve prosthesis selection and postinterventional complication rates. Cardiac magnetic resonance may play a role especially in post-TAVR assessment, as it provides both anatomic information and blood flow dynamics. This article reviews multimodality imaging approaches to pre-TAVR aortic root size assessment, provides an overview of the impact on post-TAVR complications and clinical outcome, and describes recent techniques to reduce contrast material volume in TAVR assessment with CT.
Articolo in rivista - Review Essay
Aortic stenosis; Computed tomography; Magnetic resonance imaging; Transcatheter aortic valve implantation; Transcatheter aortic valve replacement;
English
2015
30
6
349
358
reserved
Wichmann, J., Varga-Szemes, A., Suranyi, P., Bayer RR, 2., Litwin, S., De Cecco, C., et al. (2015). Transcatheter aortic valve replacement imaging techniques for aortic root sizing. JOURNAL OF THORACIC IMAGING, 30(6), 349-358 [10.1097/RTI.0000000000000167].
File in questo prodotto:
File Dimensione Formato  
Transcatheter Aortic Valve Replacement Imaging Techniques for Aortic Root Sizing.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 514.21 kB
Formato Adobe PDF
514.21 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/378627
Citazioni
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
Social impact