The High Voltage Padova Test Facility (HVPTF) is an experimental device for investigating HV insulation in vacuum, in support of the realization of MITICA, the prototype of a neutral beam injector for ITER. The facility investigates the physical phenomena underlying voltage holding in vacuum, such as the mechanisms causing breakdowns and the electrode conditioning process, along with testing technical solutions to increase the breakdown threshold. Inside a high vacuum chamber, two stainless steel electrodes, separated by a few centimetres gap, can achieve HV values for a maximum of 800 kV potential difference. The conditioning process consists of the gradual increase of the breakdown voltage in time, until the system achieves a saturation value. Between two consecutive breakdown events, current micro-discharges involving the electrodes are observed; high energy X-rays (up to hundreds of keV) and a global increase of gas emission (in particular H2 and CO2 are detected by the Residual Gas Analyser) are measured in correspondence to the current events. Two new X-rays detectors have been recently installed: a small LYSO and a LaBr3(Ce) scintillating crystals, coupled to photomultipliers. They all are small sized scintillators, with very fast pulses (40-100 ns) in order to minimize pileup effects during the high intensity discharges. However, the high Z and densities guarantee a full energy absorption of the X-rays (they can measure up to 500 keV), with a significant probability, in spite of the small sizes. In this contribution we present a characterization of the micro-discharge dynamics occurring during the conditioning phase, focusing on the new details uncovered via the new diagnostics.
Spagnolo, S., Pilan, N., de Lorenzi, A., Fontana, C., Mccormack, O., Muraro, A., et al. (2021). Characterization of X-Ray Events for a Vacuum High Voltage Holding Experiment. In ISDEIV 2020. Proceedings of the 29th International Symposium on Discharges and Electrical Insulation in Vacuum. September 26th – 30th, 2021 Padova, Italy (pp.58-61). Institute of Electrical and Electronics Engineers Inc. [10.1109/ISDEIV46977.2021.9587083].
Characterization of X-Ray Events for a Vacuum High Voltage Holding Experiment
Muraro, A;Croci, G;Gorini, G;Martines, E;Rigamonti, D;Tardocchi, M;
2021
Abstract
The High Voltage Padova Test Facility (HVPTF) is an experimental device for investigating HV insulation in vacuum, in support of the realization of MITICA, the prototype of a neutral beam injector for ITER. The facility investigates the physical phenomena underlying voltage holding in vacuum, such as the mechanisms causing breakdowns and the electrode conditioning process, along with testing technical solutions to increase the breakdown threshold. Inside a high vacuum chamber, two stainless steel electrodes, separated by a few centimetres gap, can achieve HV values for a maximum of 800 kV potential difference. The conditioning process consists of the gradual increase of the breakdown voltage in time, until the system achieves a saturation value. Between two consecutive breakdown events, current micro-discharges involving the electrodes are observed; high energy X-rays (up to hundreds of keV) and a global increase of gas emission (in particular H2 and CO2 are detected by the Residual Gas Analyser) are measured in correspondence to the current events. Two new X-rays detectors have been recently installed: a small LYSO and a LaBr3(Ce) scintillating crystals, coupled to photomultipliers. They all are small sized scintillators, with very fast pulses (40-100 ns) in order to minimize pileup effects during the high intensity discharges. However, the high Z and densities guarantee a full energy absorption of the X-rays (they can measure up to 500 keV), with a significant probability, in spite of the small sizes. In this contribution we present a characterization of the micro-discharge dynamics occurring during the conditioning phase, focusing on the new details uncovered via the new diagnostics.File | Dimensione | Formato | |
---|---|---|---|
110 - ISDEIV 21 Xray events in high voltage.pdf
Solo gestori archivio
Descrizione: Proceedings
Tipologia di allegato:
Publisher’s Version (Version of Record, VoR)
Dimensione
1.41 MB
Formato
Adobe PDF
|
1.41 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.