BACKGROUND: Long scanning times impede cardiac magnetic resonance (CMR) clinical uptake. A “one-size-fits-all” shortened, focused protocol (eg, only function and late-gadolinium enhancement) reduces scanning time and costs, but provides less information. We developed 2 question-driven CMR and stress-CMR protocols, including tailored advanced tissue characterization, and tested their effectiveness in reducing scanning time while retaining the diagnostic performances of standard protocols. METHODS AND RESULTS: Eighty three consecutive patients with cardiomyopathy or ischemic heart disease underwent the tailored CMR. Each scan consisted of standard cines, late-gadolinium enhancement imaging, native T1-mapping, and extracellular volume. Fat/edema modules, right ventricle cine, and in-line quantitative perfusion mapping were performed as clinically required. Workflow was optimized to avoid gaps. Time target was <30 minutes for a CMR and [removed]30% (CMR: from 42±8 to 28±6 minutes; stress-CMR: from 50±10 to 34±6 minutes, both P[removed]45% of cases. Quality grading was similar between the 2 protocols. Tailored protocols did not require additional staff. CONCLUSIONS: Tailored CMR and stress-CMR protocols including advanced tissue characterization are accurate and timeeffective for cardiomyopathies and ischemic heart disease.

Torlasco, C., Castelletti, S., Soranna, D., Volpato, V., Figliozzi, S., Menacho, K., et al. (2022). Effective Study: Development and Application of a Question-Driven, Time-Effective Cardiac Magnetic Resonance Scanning Protocol. JOURNAL OF THE AMERICAN HEART ASSOCIATION. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE, 11(1) [10.1161/JAHA.121.022605].

Effective Study: Development and Application of a Question-Driven, Time-Effective Cardiac Magnetic Resonance Scanning Protocol

Torlasco, Camilla
;
Soranna, Davide;Volpato, Valentina;Zambon, Antonella;Badano, Luigi;Parati, Gianfranco
2022

Abstract

BACKGROUND: Long scanning times impede cardiac magnetic resonance (CMR) clinical uptake. A “one-size-fits-all” shortened, focused protocol (eg, only function and late-gadolinium enhancement) reduces scanning time and costs, but provides less information. We developed 2 question-driven CMR and stress-CMR protocols, including tailored advanced tissue characterization, and tested their effectiveness in reducing scanning time while retaining the diagnostic performances of standard protocols. METHODS AND RESULTS: Eighty three consecutive patients with cardiomyopathy or ischemic heart disease underwent the tailored CMR. Each scan consisted of standard cines, late-gadolinium enhancement imaging, native T1-mapping, and extracellular volume. Fat/edema modules, right ventricle cine, and in-line quantitative perfusion mapping were performed as clinically required. Workflow was optimized to avoid gaps. Time target was <30 minutes for a CMR and [removed]30% (CMR: from 42±8 to 28±6 minutes; stress-CMR: from 50±10 to 34±6 minutes, both P[removed]45% of cases. Quality grading was similar between the 2 protocols. Tailored protocols did not require additional staff. CONCLUSIONS: Tailored CMR and stress-CMR protocols including advanced tissue characterization are accurate and timeeffective for cardiomyopathies and ischemic heart disease.
Articolo in rivista - Articolo scientifico
Cardiomyopathy; Cardiovascular magnetic resonance; Ischemic heart disease; Rapid scanning; Time-effectiveness;
English
31-dic-2021
2022
11
1
e022605
open
Torlasco, C., Castelletti, S., Soranna, D., Volpato, V., Figliozzi, S., Menacho, K., et al. (2022). Effective Study: Development and Application of a Question-Driven, Time-Effective Cardiac Magnetic Resonance Scanning Protocol. JOURNAL OF THE AMERICAN HEART ASSOCIATION. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE, 11(1) [10.1161/JAHA.121.022605].
File in questo prodotto:
File Dimensione Formato  
10281-347792_VoR.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 757.38 kB
Formato Adobe PDF
757.38 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/347792
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact