POLARBEAR-2A is the first receiver for the Simons Array cosmic microwave background polarization experiment. POLARBEAR-2A has transition-edge sensor bolometers on the focal plane. Signals from bolometers are multiplexed and read out by a single SQUID. The receiver was deployed in late 2018 in Atacama, Chile, and operation started in 2019, where rapid confirmation of correspondence between bolometers and multiplexed readout channels was important as an initial step of performance validation. For this purpose, we devised a method using a coherent source that allows us to identify the frequency band and polarization sensitivity angle for each readout channel without detailed bolometer tuning.
Segawa, Y., Hirose, H., Kaneko, D., Hasegawa, M., Adachi, S., Ade, P., et al. (2021). Method for rapid performance validation of large TES bolometer array for POLARBEAR-2A using a coherent millimeter-wave source. In AIP Conference Proceedings. American Institute of Physics Inc. [10.1063/5.0038197].
Method for rapid performance validation of large TES bolometer array for POLARBEAR-2A using a coherent millimeter-wave source
Segawa Y.
;Hirose H.;Kaneko D.;Hasegawa M.;Adachi S.;Ade P.;Faundez M. A. O. A.;Akiba Y.;Arnold K.;Avva J.;Baccigalupi C.;Barron D.;Beck D.;Beckman S.;Bianchini F.;Boettger D.;Borrill J.;Carron J.;Chapman S.;Cheung K.;Chinone Y.;Crowley K.;Cukierman A.;De Haan T.;Dobbs M.;Dunner R.;Bouhargani H. E.;Elleflot T.;Errard J.;Fabbian G.;Feeney S.;Feng C.;Fujino T.;Galitzki N.;Goeckner-Wald N.;Groh J.;Hall G.;Halverson N.;Hamada T.;Hazumi M.;Hill C.;Howe L.;Inoue Y.;Ito J.;Jaehnig G.;Jeong O.;Katayama N.;Keating B.;Keskitalo R.;Kikuchi S.;Kisner T.;Krachmalnicoff N.;Kusaka A.;Lee A. T.;Leon D.;Linder E.;Lowry L. N.;Mangu A.;Matsuda F.;Minami Y.;Montgomery J.;Navaroli M.;Nishino H.;Peloton J.;Pham A. T. P.;Poletti D.;Puglisi G.;Raum C.;Reichardt C. L.;Ross C.;Silva-Feaver M.;Siritanasak P.;Stompor R.;Suzuki A.;Tajima O.;Takakura S.;Takatori S.;Tanabe D.;Teply G. P.;Tsai C.;Verges C.;Westbrook B.;Zhou Y.
2021
Abstract
POLARBEAR-2A is the first receiver for the Simons Array cosmic microwave background polarization experiment. POLARBEAR-2A has transition-edge sensor bolometers on the focal plane. Signals from bolometers are multiplexed and read out by a single SQUID. The receiver was deployed in late 2018 in Atacama, Chile, and operation started in 2019, where rapid confirmation of correspondence between bolometers and multiplexed readout channels was important as an initial step of performance validation. For this purpose, we devised a method using a coherent source that allows us to identify the frequency band and polarization sensitivity angle for each readout channel without detailed bolometer tuning.
Segawa, Y., Hirose, H., Kaneko, D., Hasegawa, M., Adachi, S., Ade, P., et al. (2021). Method for rapid performance validation of large TES bolometer array for POLARBEAR-2A using a coherent millimeter-wave source. In AIP Conference Proceedings. American Institute of Physics Inc. [10.1063/5.0038197].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/319871
Citazioni
1
1
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.