Purpose: Stereopsis is a fundamental skill in human vision and visual actions. There are many ways to test and quantify stereoacuity: traditional paper and new digital applications are both valid ways to test the stereoacuity. The aim of this study is to compare the results obtained using standard tests and the new Stereoacuity Test App developed by the University of Bergamo. Methods: A group of 497 children (272 males), aged between 6 and 11 years old, were tested using different tests for the quantification of stereopsis at near. These tests were TNO, Weiss EKW, and the new developed Stereoacuity Test App. Results: A one-way repeated measure ANOVA showed that the three tests give different thresholds of stereoacuity (p < 0.0001). Post hoc analyses with Bonferroni correction showed that all tests showed different thresholds (p < 0.0001). The lower threshold was obtained by Titmus Stereo Test followed by Stereoacuity App, Weiss MKW, and TNO. Conclusion: The stereoacuity based on global stereopsis showed that the better values were obtained in order by Stereoacuity Test App, TNO, and Weiss EKW. However, the clinical significance of their values is similar. The new digital test showed a greater compliance by the child, showing itself in tune with the digital characteristics of today’s children.

Bonfanti, S., Gargantini, A., Esposito, G., Facchin, A., Maffioletti, M., Maffioletti, S. (2021). Evaluation of stereoacuity with a digital mobile application. GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 259(9), 2843-2848 [10.1007/s00417-021-05195-z].

Evaluation of stereoacuity with a digital mobile application

Facchin A.;Maffioletti S.
2021

Abstract

Purpose: Stereopsis is a fundamental skill in human vision and visual actions. There are many ways to test and quantify stereoacuity: traditional paper and new digital applications are both valid ways to test the stereoacuity. The aim of this study is to compare the results obtained using standard tests and the new Stereoacuity Test App developed by the University of Bergamo. Methods: A group of 497 children (272 males), aged between 6 and 11 years old, were tested using different tests for the quantification of stereopsis at near. These tests were TNO, Weiss EKW, and the new developed Stereoacuity Test App. Results: A one-way repeated measure ANOVA showed that the three tests give different thresholds of stereoacuity (p < 0.0001). Post hoc analyses with Bonferroni correction showed that all tests showed different thresholds (p < 0.0001). The lower threshold was obtained by Titmus Stereo Test followed by Stereoacuity App, Weiss MKW, and TNO. Conclusion: The stereoacuity based on global stereopsis showed that the better values were obtained in order by Stereoacuity Test App, TNO, and Weiss EKW. However, the clinical significance of their values is similar. The new digital test showed a greater compliance by the child, showing itself in tune with the digital characteristics of today’s children.
Articolo in rivista - Articolo scientifico
Anaglyph colors; Binocular vision; Digital stereotest; Global stereopsis; Randot stereotest; Stereo threshold; Stereoacuity;
English
2021
259
9
2843
2848
open
Bonfanti, S., Gargantini, A., Esposito, G., Facchin, A., Maffioletti, M., Maffioletti, S. (2021). Evaluation of stereoacuity with a digital mobile application. GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 259(9), 2843-2848 [10.1007/s00417-021-05195-z].
File in questo prodotto:
File Dimensione Formato  
Bonfanti et al 2021 Stereoacuity Smartphone.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 742.59 kB
Formato Adobe PDF
742.59 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/316046
Citazioni
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
Social impact