Background and Aims: Liver fibrosis holds a relevant prognostic meaning in primary biliary cholangitis (PBC). Noninvasive fibrosis evaluation using vibration-controlled transient elastography (VCTE) is routinely performed. However, there is limited evidence on its accuracy at diagnosis in PBC. We aimed to estimate the diagnostic accuracy of VCTE in assessing advanced fibrosis (AF) at disease presentation in PBC. Approach and Results: We collected data from 167 consecutive treatment-naïve PBC patients who underwent liver biopsy (LB) at diagnosis at six Italian centers. VCTE examinations were completed within 12 weeks of LB. Biopsies were scored by two blinded expert pathologists, according to the Ludwig system. Diagnostic accuracy was estimated using the area under the receiver operating characteristic curves (AUROCs) for AF (Ludwig stage ≥III). Effects of biochemical and clinical parameters on liver stiffness measurement (LSM) were appraised. The derivation cohort consisted of 126 patients with valid LSM and LB; VCTE identified patients with AF with an AUROC of 0.89. LSM cutoffs ≤6.5 and >11.0 kPa enabled to exclude and confirm, respectively, AF (negative predictive value [NPV] = 0.94; positive predictive value [PPV] = 0.89; error rate = 5.6%). These values were externally validated in an independent cohort of 91 PBC patients (NPV = 0.93; PPV = 0.89; error rate = 8.6%). Multivariable analysis found that the only parameter affecting LSM was fibrosis stage. No association was found with BMI and liver biochemistry. Conclusions: In a multicenter study of treatment-naïve PBC patients, we identified two cutoffs (LSM ≤6.5 and >11.0 kPa) able to discriminate at diagnosis the absence or presence, respectively, of AF in PBC patients, with external validation. In patients with LSM between these two cutoffs, VCTE is not reliable and liver biopsy should be evaluated for accurate disease staging. BMI and liver biochemistry did not affect LSMs.

Cristoferi, L., Calvaruso, V., Overi, D., Viganò, M., Rigamonti, C., Degasperi, E., et al. (2021). Accuracy of Transient Elastography in assessing fibrosis at diagnosis in naïve patients with Primary Biliary Cholangitis: a dual cut-off approach. HEPATOLOGY, 74(3), 1496-1508 [10.1002/hep.31810].

Accuracy of Transient Elastography in assessing fibrosis at diagnosis in naïve patients with Primary Biliary Cholangitis: a dual cut-off approach

Cristoferi, Laura;Lucà, Martina;Gerussi, Alessio;Malinverno, Federica;Ronca, Vincenzo;Mancuso, Clara;Ciaccio, Antonio;Barisani, Donatella;Invernizzi, Pietro;Carbone, Marco
2021

Abstract

Background and Aims: Liver fibrosis holds a relevant prognostic meaning in primary biliary cholangitis (PBC). Noninvasive fibrosis evaluation using vibration-controlled transient elastography (VCTE) is routinely performed. However, there is limited evidence on its accuracy at diagnosis in PBC. We aimed to estimate the diagnostic accuracy of VCTE in assessing advanced fibrosis (AF) at disease presentation in PBC. Approach and Results: We collected data from 167 consecutive treatment-naïve PBC patients who underwent liver biopsy (LB) at diagnosis at six Italian centers. VCTE examinations were completed within 12 weeks of LB. Biopsies were scored by two blinded expert pathologists, according to the Ludwig system. Diagnostic accuracy was estimated using the area under the receiver operating characteristic curves (AUROCs) for AF (Ludwig stage ≥III). Effects of biochemical and clinical parameters on liver stiffness measurement (LSM) were appraised. The derivation cohort consisted of 126 patients with valid LSM and LB; VCTE identified patients with AF with an AUROC of 0.89. LSM cutoffs ≤6.5 and >11.0 kPa enabled to exclude and confirm, respectively, AF (negative predictive value [NPV] = 0.94; positive predictive value [PPV] = 0.89; error rate = 5.6%). These values were externally validated in an independent cohort of 91 PBC patients (NPV = 0.93; PPV = 0.89; error rate = 8.6%). Multivariable analysis found that the only parameter affecting LSM was fibrosis stage. No association was found with BMI and liver biochemistry. Conclusions: In a multicenter study of treatment-naïve PBC patients, we identified two cutoffs (LSM ≤6.5 and >11.0 kPa) able to discriminate at diagnosis the absence or presence, respectively, of AF in PBC patients, with external validation. In patients with LSM between these two cutoffs, VCTE is not reliable and liver biopsy should be evaluated for accurate disease staging. BMI and liver biochemistry did not affect LSMs.
Articolo in rivista - Articolo scientifico
diagnostic accuracy; fibrosis; primary biliary cholangitis; risk stratification; transient elastography;
English
16-mar-2021
2021
74
3
1496
1508
open
Cristoferi, L., Calvaruso, V., Overi, D., Viganò, M., Rigamonti, C., Degasperi, E., et al. (2021). Accuracy of Transient Elastography in assessing fibrosis at diagnosis in naïve patients with Primary Biliary Cholangitis: a dual cut-off approach. HEPATOLOGY, 74(3), 1496-1508 [10.1002/hep.31810].
File in questo prodotto:
File Dimensione Formato  
10281-315478_VoR.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Licenza: Creative Commons
Dimensione 362.84 kB
Formato Adobe PDF
362.84 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/315478
Citazioni
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 32
Social impact