The neutron and gamma radiations in large fusion reactors are responsible for damage to charged couple device (CCD) cameras deployed for applied diagnostics. Based on the ASTM guide E722-09, the 'equivalent 1 MeV neutron fluence in silicon' was calculated for a set of CCD cameras at the Joint European Torus. Such evaluations would be useful to good practice in the operation of the video systems.
Milocco, A., Conroy, S., Popovichev, S., Sergienko, G., Huber, A. (2018). Neutron radiation damage In CCD cameras at the Joint European Torus (JET). RADIATION PROTECTION DOSIMETRY, 180(1-4), 109-114 [10.1093/rpd/ncx220].
Neutron radiation damage In CCD cameras at the Joint European Torus (JET)
A. Milocco
Primo
;
2018
Abstract
The neutron and gamma radiations in large fusion reactors are responsible for damage to charged couple device (CCD) cameras deployed for applied diagnostics. Based on the ASTM guide E722-09, the 'equivalent 1 MeV neutron fluence in silicon' was calculated for a set of CCD cameras at the Joint European Torus. Such evaluations would be useful to good practice in the operation of the video systems.File in questo prodotto: