The 1-ton-scale CUORE detector is made of 988 TeO 2 crystals operated as cryogenic bolometers at a working temperature of ∼10mK. In order to provide the necessary cooling power at 4 K stage, a total of five pulse tube (PT) refrigerators are used. The PTs make the cryogenic system reliable and stable, but have the downside that mechanical vibrations at low frequencies (1.4 Hz and related harmonics) are injected into the experimental apparatus. An active noise cancellation technique has been developed in order to reduce such effect by taking advantage from the coherent interference of the pressure oscillations originated by the different PTs. The technique that will be presented consists in controlling the relative phases of the pressure waves running inside the CUORE PT lines, in order to achieve the lowest detector noise. By reducing the power of PT harmonics by a factor up to 10 4, it drastically suppresses the overall noise RMS on the CUORE detector. In the following, we demonstrate the reliability and effectiveness of the technique, showing that the optimization of the detector noise level is possible in different experimental conditions.

Dompe, V., Bucci, C., Canonica, L., D'Addabbo, A., Di Domizio, S., Fantini, G., et al. (2020). The CUORE Pulse Tube Noise Cancellation Technique. JOURNAL OF LOW TEMPERATURE PHYSICS, 200(5-6), 286-294 [10.1007/s10909-020-02435-0].

The CUORE Pulse Tube Noise Cancellation Technique

Canonica L.;Gorla P.;Nucciotti A.;Nutini I.;
2020

Abstract

The 1-ton-scale CUORE detector is made of 988 TeO 2 crystals operated as cryogenic bolometers at a working temperature of ∼10mK. In order to provide the necessary cooling power at 4 K stage, a total of five pulse tube (PT) refrigerators are used. The PTs make the cryogenic system reliable and stable, but have the downside that mechanical vibrations at low frequencies (1.4 Hz and related harmonics) are injected into the experimental apparatus. An active noise cancellation technique has been developed in order to reduce such effect by taking advantage from the coherent interference of the pressure oscillations originated by the different PTs. The technique that will be presented consists in controlling the relative phases of the pressure waves running inside the CUORE PT lines, in order to achieve the lowest detector noise. By reducing the power of PT harmonics by a factor up to 10 4, it drastically suppresses the overall noise RMS on the CUORE detector. In the following, we demonstrate the reliability and effectiveness of the technique, showing that the optimization of the detector noise level is possible in different experimental conditions.
Articolo in rivista - Articolo scientifico
Cryostat; Noise reduction; Pulse tube refrigerators
English
24-mar-2020
2020
200
5-6
286
294
reserved
Dompe, V., Bucci, C., Canonica, L., D'Addabbo, A., Di Domizio, S., Fantini, G., et al. (2020). The CUORE Pulse Tube Noise Cancellation Technique. JOURNAL OF LOW TEMPERATURE PHYSICS, 200(5-6), 286-294 [10.1007/s10909-020-02435-0].
File in questo prodotto:
File Dimensione Formato  
Dompè2020_Article_TheCUOREPulseTubeNoiseCancella.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 2.88 MB
Formato Adobe PDF
2.88 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/290396
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
Social impact