Objectives: To evaluate aortic distensibility and pulse waveform patterns associated with the ascending aortic aneurysm, and to analyze the postoperative and mid-term hemodynamic changes induced by prosthetic replacement of the ascending aorta. Methods: Central blood pressure waves were recorded at the carotid artery level by means of a validated transcutaneous arterial tonometer in 30 patients undergoing prosthetic replacement of ascending aortic aneurysm and in 30 control patients. Measurements were obtained the day before surgery and 5 to 7 days and 16 to 20 months after surgery. Results: The ascending aortic aneurysm was associated with a less steep slope of early systolic phase of the pressure curve (pulsus tardus) compared with a control group (0.54 ± 0.18 mm Hg/ms vs 0.69 ± 0.26 mm Hg/ms; P = .011). Replacing the ascending aorta with a noncompliant vascular prosthesis steepened the pulse pressure slope during the early systolic phase in the postoperative period (0.77 ± .29 mm Hg/ms), providing values comparable with those of the control group in the mid-term (0.67 ± .20 mm Hg/ms). No change in aortic stiffness was found either postoperatively or in the mid-term after ascending aorta surgical replacement (carotid-femoral pulse wave velocity: preoperative, 9.0 ± 2.6 m/s; postoperative, 9.0 ± 2.9 m/s; mid-term postoperative, 9.3 ± 2.8 m/s). Conclusions: This study does not confirm the assumption that substitution of the viscoelastic ascending aorta with a rigid prosthesis can cause serious hemodynamic alterations downstream, because we did not observe a worsening of global aortic distensibility after insertion of a rigid prosthetic aorta. The ascending aortic aneurysm is associated with a pulsus tardus.

Salvi, L., Alfonsi, J., Grillo, A., Pini, A., Soranna, D., Zambon, A., et al. (2022). Postoperative and mid-term hemodynamic changes after replacement of the ascending aorta. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 163(4 (April 2022)), 1283-1292 [10.1016/j.jtcvs.2020.05.031].

Postoperative and mid-term hemodynamic changes after replacement of the ascending aorta

Grillo A.;Soranna D.;Zambon A.;Parati G.
2022

Abstract

Objectives: To evaluate aortic distensibility and pulse waveform patterns associated with the ascending aortic aneurysm, and to analyze the postoperative and mid-term hemodynamic changes induced by prosthetic replacement of the ascending aorta. Methods: Central blood pressure waves were recorded at the carotid artery level by means of a validated transcutaneous arterial tonometer in 30 patients undergoing prosthetic replacement of ascending aortic aneurysm and in 30 control patients. Measurements were obtained the day before surgery and 5 to 7 days and 16 to 20 months after surgery. Results: The ascending aortic aneurysm was associated with a less steep slope of early systolic phase of the pressure curve (pulsus tardus) compared with a control group (0.54 ± 0.18 mm Hg/ms vs 0.69 ± 0.26 mm Hg/ms; P = .011). Replacing the ascending aorta with a noncompliant vascular prosthesis steepened the pulse pressure slope during the early systolic phase in the postoperative period (0.77 ± .29 mm Hg/ms), providing values comparable with those of the control group in the mid-term (0.67 ± .20 mm Hg/ms). No change in aortic stiffness was found either postoperatively or in the mid-term after ascending aorta surgical replacement (carotid-femoral pulse wave velocity: preoperative, 9.0 ± 2.6 m/s; postoperative, 9.0 ± 2.9 m/s; mid-term postoperative, 9.3 ± 2.8 m/s). Conclusions: This study does not confirm the assumption that substitution of the viscoelastic ascending aorta with a rigid prosthesis can cause serious hemodynamic alterations downstream, because we did not observe a worsening of global aortic distensibility after insertion of a rigid prosthetic aorta. The ascending aortic aneurysm is associated with a pulsus tardus.
Articolo in rivista - Articolo scientifico
aortic distensibility; arterial stiffness; ascending aortic aneurysm; pulse wave velocity; thoracic aortic surgery; vascular prosthesis;
English
27-mag-2020
2022
163
4 (April 2022)
1283
1292
none
Salvi, L., Alfonsi, J., Grillo, A., Pini, A., Soranna, D., Zambon, A., et al. (2022). Postoperative and mid-term hemodynamic changes after replacement of the ascending aorta. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 163(4 (April 2022)), 1283-1292 [10.1016/j.jtcvs.2020.05.031].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/286723
Citazioni
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
Social impact