Background: Fluid challenges (FCs) are one of the most commonly used therapies in critically ill patients and represent the cornerstone of hemodynamic management in intensive care units. There are clear benefits and harms from fluid therapy. Limited data on the indication, type, amount and rate of an FC in critically ill patients exist in the literature. The primary aim was to evaluate how physicians conduct FCs in terms of type, volume, and rate of given fluid; the secondary aim was to evaluate variables used to trigger an FC and to compare the proportion of patients receiving further fluid administration based on the response to the FC. Methods: This was an observational study conducted in ICUs around the world. Each participating unit entered a maximum of 20 patients with one FC. Results: 2213 patients were enrolled and analyzed in the study. The median [interquartile range] amount of fluid given during an FC was 500 ml (500–1000). The median time was 24 min (40–60 min), and the median rate of FC was 1000 [500–1333] ml/h. The main indication for FC was hypotension in 1211 (59 %, CI 57–61 %). In 43 % (CI 41–45 %) of the cases no hemodynamic variable was used. Static markers of preload were used in 785 of 2213 cases (36 %, CI 34–37 %). Dynamic indices of preload responsiveness were used in 483 of 2213 cases (22 %, CI 20–24 %). No safety variable for the FC was used in 72 % (CI 70–74 %) of the cases. There was no statistically significant difference in the proportion of patients who received further fluids after the FC between those with a positive, with an uncertain or with a negatively judged response. Conclusions: The current practice and evaluation of FC in critically ill patients are highly variable. Prediction of fluid responsiveness is not used routinely, safety limits are rarely used, and information from previous failed FCs is not always taken into account.

Cecconi, M., Hofer, C., Teboul, J., Pettila, V., Wilkman, E., Molnar, Z., et al. (2015). Fluid challenges in intensive care: the FENICE study: A global inception cohort study. INTENSIVE CARE MEDICINE, 41(9), 1529-1537 [10.1007/s00134-015-3850-x].

Fluid challenges in intensive care: the FENICE study: A global inception cohort study

Citerio G.;Brazzi L.;Foti G.;
2015

Abstract

Background: Fluid challenges (FCs) are one of the most commonly used therapies in critically ill patients and represent the cornerstone of hemodynamic management in intensive care units. There are clear benefits and harms from fluid therapy. Limited data on the indication, type, amount and rate of an FC in critically ill patients exist in the literature. The primary aim was to evaluate how physicians conduct FCs in terms of type, volume, and rate of given fluid; the secondary aim was to evaluate variables used to trigger an FC and to compare the proportion of patients receiving further fluid administration based on the response to the FC. Methods: This was an observational study conducted in ICUs around the world. Each participating unit entered a maximum of 20 patients with one FC. Results: 2213 patients were enrolled and analyzed in the study. The median [interquartile range] amount of fluid given during an FC was 500 ml (500–1000). The median time was 24 min (40–60 min), and the median rate of FC was 1000 [500–1333] ml/h. The main indication for FC was hypotension in 1211 (59 %, CI 57–61 %). In 43 % (CI 41–45 %) of the cases no hemodynamic variable was used. Static markers of preload were used in 785 of 2213 cases (36 %, CI 34–37 %). Dynamic indices of preload responsiveness were used in 483 of 2213 cases (22 %, CI 20–24 %). No safety variable for the FC was used in 72 % (CI 70–74 %) of the cases. There was no statistically significant difference in the proportion of patients who received further fluids after the FC between those with a positive, with an uncertain or with a negatively judged response. Conclusions: The current practice and evaluation of FC in critically ill patients are highly variable. Prediction of fluid responsiveness is not used routinely, safety limits are rarely used, and information from previous failed FCs is not always taken into account.
Articolo in rivista - Articolo scientifico
HYDROXYETHYL STARCH 130/0.4; RENAL REPLACEMENT THERAPY; CRITICALLY-ILL PATIENTS; OF-THE-LITERATURE; SEPTIC SHOCK; SEVERE SEPSIS; CIRCULATORY SHOCK; ARTERIAL-PRESSURE; TASK-FORCE; RESPONSIVENESS
English
2015
41
9
1529
1537
partially_open
Cecconi, M., Hofer, C., Teboul, J., Pettila, V., Wilkman, E., Molnar, Z., et al. (2015). Fluid challenges in intensive care: the FENICE study: A global inception cohort study. INTENSIVE CARE MEDICINE, 41(9), 1529-1537 [10.1007/s00134-015-3850-x].
File in questo prodotto:
File Dimensione Formato  
10281-281559.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 411.85 kB
Formato Adobe PDF
411.85 kB Adobe PDF Visualizza/Apri
Fluid-challenges-in-intensive-care-the-FENICE-study-A-global-inception-cohort-study2015Intensive-Care-Medicine.pdf

Solo gestori archivio

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 411.85 kB
Formato Adobe PDF
411.85 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/281559
Citazioni
  • Scopus 427
  • ???jsp.display-item.citation.isi??? 389
Social impact