Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
Background: Continuous subcutaneous insulin infusion (CSII) is increasing worldwide, mostly because of improved technology. The aim of this study was to evaluate the current status of CSII in Italy. Materials and Methods: Physicians from 272 diabetes centers received a questionnaire investigating clinical features, pump technology, and management of patients on CSII. Results: Two hundred seventeen centers (79.8%) joined the study and, by the end of April 2013, gave information about 10,152 patients treated with CSII: 98.2% with type 1 diabetes mellitus, 81.4% adults, 57% female, and 61% with a conventional pump versus 39% with a sensor-augmented pump. CSII advanced functions were used by 68% of patients, and glucose sensors were used 12 days per month on average. Fifty-eight percent of diabetes centers had more than 20 patients on CSII, but there were differences among centers and among regions. The main indication for CSII was poor glucose control. Dropout was mainly due to pump wearability or nonoptimal glycemic control. Twenty-four hour assistance was guaranteed in 81% of centers. A full diabetes team (physician+ nurse + dietician + psychologist) was available in 23% of adult-care diabetes centers and in 53%of pediatric diabetes units. Conclusions: CSII keeps increasing in Italy. More work is needed to ensure uniform treatment strategies throughout the country and to improve pump use.
Bruttomesso, D., Laviola, L., Lepore, G., Bonfanti, R., Bozzetto, L., Corsi, A., et al. (2015). Continuous subcutaneous insulin infusion in Italy: Third national survey. DIABETES TECHNOLOGY & THERAPEUTICS, 17(2), 96-104 [10.1089/dia.2014.0242].
Continuous subcutaneous insulin infusion in Italy: Third national survey
Background: Continuous subcutaneous insulin infusion (CSII) is increasing worldwide, mostly because of improved technology. The aim of this study was to evaluate the current status of CSII in Italy. Materials and Methods: Physicians from 272 diabetes centers received a questionnaire investigating clinical features, pump technology, and management of patients on CSII. Results: Two hundred seventeen centers (79.8%) joined the study and, by the end of April 2013, gave information about 10,152 patients treated with CSII: 98.2% with type 1 diabetes mellitus, 81.4% adults, 57% female, and 61% with a conventional pump versus 39% with a sensor-augmented pump. CSII advanced functions were used by 68% of patients, and glucose sensors were used 12 days per month on average. Fifty-eight percent of diabetes centers had more than 20 patients on CSII, but there were differences among centers and among regions. The main indication for CSII was poor glucose control. Dropout was mainly due to pump wearability or nonoptimal glycemic control. Twenty-four hour assistance was guaranteed in 81% of centers. A full diabetes team (physician+ nurse + dietician + psychologist) was available in 23% of adult-care diabetes centers and in 53%of pediatric diabetes units. Conclusions: CSII keeps increasing in Italy. More work is needed to ensure uniform treatment strategies throughout the country and to improve pump use.
Bruttomesso, D., Laviola, L., Lepore, G., Bonfanti, R., Bozzetto, L., Corsi, A., et al. (2015). Continuous subcutaneous insulin infusion in Italy: Third national survey. DIABETES TECHNOLOGY & THERAPEUTICS, 17(2), 96-104 [10.1089/dia.2014.0242].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/280294
Citazioni
19
17
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.