OBJECTIVE: To evaluate image quality and radiation dose exposure of low-kV setting and low-volume contrast medium (CM) computed tomography angiography (CTA) protocol for transcatheter aortic valve implantation (TAVI) planning in comparison with standard CTA protocol. METHODS: Sixty-patients were examined with 256-row MDCT for TAVI planning: 32 patients (study group) were evaluated using 80-kV electrocardiogram-gated protocol with 60 mL of CM and IMR reconstruction; 28 patients underwent a standard electrocardiogram-gated CTA study (100 kV; 80 mL of CM; iDose4 reconstruction). Subjective and objective image quality was evaluated in each patient at different aortic levels. Finally, we collected radiation dose exposure data (CT dose index and dose-length product) of both groups. RESULTS: In study protocol, significant higher mean attenuation values were achieved in all measurements compared with the standard protocol. There were no significant differences in the subjective image quality evaluation in both groups. Mean dose-length product of study group was 56% lower than in the control one (P < 0.0001). CONCLUSION: Low-kV and low-CM volume CTA, combined with IMR, allows to correctly performing TAVI planning with high-quality images and significant radiation dose reduction compared with standard CTA protocol.

Ippolito, D., Riva, L., Talei Franzesi, C., De Vito, A., Cangiotti, C., Crespi, A., et al. (2020). Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 44(1), 13-19 [10.1097/RCT.0000000000000965].

Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol

Ippolito D.
;
Riva L.;Talei Franzesi C.;De Vito A.;Cangiotti C.;Crespi A.;Sironi S.
2020

Abstract

OBJECTIVE: To evaluate image quality and radiation dose exposure of low-kV setting and low-volume contrast medium (CM) computed tomography angiography (CTA) protocol for transcatheter aortic valve implantation (TAVI) planning in comparison with standard CTA protocol. METHODS: Sixty-patients were examined with 256-row MDCT for TAVI planning: 32 patients (study group) were evaluated using 80-kV electrocardiogram-gated protocol with 60 mL of CM and IMR reconstruction; 28 patients underwent a standard electrocardiogram-gated CTA study (100 kV; 80 mL of CM; iDose4 reconstruction). Subjective and objective image quality was evaluated in each patient at different aortic levels. Finally, we collected radiation dose exposure data (CT dose index and dose-length product) of both groups. RESULTS: In study protocol, significant higher mean attenuation values were achieved in all measurements compared with the standard protocol. There were no significant differences in the subjective image quality evaluation in both groups. Mean dose-length product of study group was 56% lower than in the control one (P < 0.0001). CONCLUSION: Low-kV and low-CM volume CTA, combined with IMR, allows to correctly performing TAVI planning with high-quality images and significant radiation dose reduction compared with standard CTA protocol.
Articolo in rivista - Articolo scientifico
computed tomography angiography; knowledge-based algorithms; low contrast medium; low radiation dose; TAVI; Adult; Aged; Aged, 80 and over; Algorithms; Aortic Valve Stenosis; Computed Tomography Angiography; Contrast Media; Humans; Female; Knowledge Bases; Male; Middle Aged; Multidetector Computed Tomography; Preoperative Period; Radiation Dosage; Radiographic Image Interpretation; Computer-Assisted; Transcatheter Aortic Valve Replacement;
English
2020
44
1
13
19
none
Ippolito, D., Riva, L., Talei Franzesi, C., De Vito, A., Cangiotti, C., Crespi, A., et al. (2020). Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 44(1), 13-19 [10.1097/RCT.0000000000000965].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/277884
Citazioni
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
Social impact