For the future JET deuterium-tritium (DT) campaigns numerous gamma-ray diagnostics, in particular the JET Gamma-ray Camera (GC) and the JET Gamma-ray Spectrometer (GS), were upgraded in the last few years. The upgrade of GC and GS included replacement of detector modules in order to allow operation at expected high count rate of ∼0.5 Mcps on the scintillator front surface of 506 mm 2 for each GC crystal and 7 squared inches for GS as well as to improve energy resolution to equal or better than 5% at gamma-ray energy above 1.1 MeV for both diagnostics. Within the JET4 Enhancements Project, performance of a number of photodetectors including multi-pixel photon counter (MPPC), PIN diode and photomultiplier tube (PMT) connected to scintillators was investigated. Upgraded detector modules are based on fast scintillators with a decay time of about 20 ns, LaBr 3 :Ce and CeBr 3 , coupled to MPPC and PMT for GC and GS, respectively. Results on energy resolution obtained with upgraded diagnostics, already installed at JET, are presented and compared to those collected in laboratory conditions.

Zychor, I., Broslawski, A., Korolczuk, S., Urban, A., Boltruczyk, G., Gosk, M., et al. (2019). Upgraded gamma-ray diagnostics for DT campaigns at JET. FUSION ENGINEERING AND DESIGN, 146, 1007-1010 [10.1016/j.fusengdes.2019.01.144].

Upgraded gamma-ray diagnostics for DT campaigns at JET

Giacomelli L.;Gorini G.;Nocente M.;Rigamonti D.;Tardocchi M.
2019

Abstract

For the future JET deuterium-tritium (DT) campaigns numerous gamma-ray diagnostics, in particular the JET Gamma-ray Camera (GC) and the JET Gamma-ray Spectrometer (GS), were upgraded in the last few years. The upgrade of GC and GS included replacement of detector modules in order to allow operation at expected high count rate of ∼0.5 Mcps on the scintillator front surface of 506 mm 2 for each GC crystal and 7 squared inches for GS as well as to improve energy resolution to equal or better than 5% at gamma-ray energy above 1.1 MeV for both diagnostics. Within the JET4 Enhancements Project, performance of a number of photodetectors including multi-pixel photon counter (MPPC), PIN diode and photomultiplier tube (PMT) connected to scintillators was investigated. Upgraded detector modules are based on fast scintillators with a decay time of about 20 ns, LaBr 3 :Ce and CeBr 3 , coupled to MPPC and PMT for GC and GS, respectively. Results on energy resolution obtained with upgraded diagnostics, already installed at JET, are presented and compared to those collected in laboratory conditions.
Articolo in rivista - Articolo scientifico
Energy resolution; Gamma-ray spectrometry; Photodetectors; Scintillators; Tokamak
English
15-feb-2019
2019
146
1007
1010
none
Zychor, I., Broslawski, A., Korolczuk, S., Urban, A., Boltruczyk, G., Gosk, M., et al. (2019). Upgraded gamma-ray diagnostics for DT campaigns at JET. FUSION ENGINEERING AND DESIGN, 146, 1007-1010 [10.1016/j.fusengdes.2019.01.144].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/269992
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact