Purpose: : To compare the central and peripheral (< 2 mm from the limbus) endothelial regions of the human cornea of young contact lens (CL) neophytes, in terms of endothelial cell density (ECD), polymorphism through cell hexagonality (HEX), and polymegethism through the coefficient of variation of cell areas (CoV). Materials and methods: : In vivo, central, temporal, and nasal ECDs, HEXs, and CoVs were determined for thirty healthy right eyes (age: 22–30 years) using a Takagi 700 G L LED slit-lamp biomicroscope equipped with the centre-dot EndoKer© for the analysis of endothelium images. Results: : The mean central ECD (2586 ± 233 mm−2) was lower than peripheral ECDs (nasal 2733 ± 225 mm−2, temporal 2674 ± 260 mm−2) (p = 0.03 and p = 0.02, respectively). The mean central HEX (53.0 ± 4.6%) was lower than peripheral HEXs (nasal 57.2 ± 4.3%, temporal 57.1 ± 4.5%) (both p < 0.005), while the mean central CoV (28.2 ± 2.5%) was higher than peripheral CoVs (nasal 25.8 ± 2.2%, temporal 26.1 ± 2.2%) (both p ≤ 0.001). Conclusions: : In young healthy non-CL wearers, the peripheral corneal endothelium displays a higher ECD and significantly better cell regularity (higher HEX and lower CoV) compared to the central cornea. A clinical evaluation of the corneal endothelium requires, therefore, a full characterization of the different areas.

Tavazzi, S., Cozza, F., Colciago, S., Zeri, F. (2020). Slit-lamp based assessment of peripheral versus central regions of the human corneal endothelium. CONTACT LENS & ANTERIOR EYE, 43(2), 149-153 [10.1016/j.clae.2019.08.002].

Slit-lamp based assessment of peripheral versus central regions of the human corneal endothelium

Tavazzi, S;Cozza, F;Zeri, F
2020

Abstract

Purpose: : To compare the central and peripheral (< 2 mm from the limbus) endothelial regions of the human cornea of young contact lens (CL) neophytes, in terms of endothelial cell density (ECD), polymorphism through cell hexagonality (HEX), and polymegethism through the coefficient of variation of cell areas (CoV). Materials and methods: : In vivo, central, temporal, and nasal ECDs, HEXs, and CoVs were determined for thirty healthy right eyes (age: 22–30 years) using a Takagi 700 G L LED slit-lamp biomicroscope equipped with the centre-dot EndoKer© for the analysis of endothelium images. Results: : The mean central ECD (2586 ± 233 mm−2) was lower than peripheral ECDs (nasal 2733 ± 225 mm−2, temporal 2674 ± 260 mm−2) (p = 0.03 and p = 0.02, respectively). The mean central HEX (53.0 ± 4.6%) was lower than peripheral HEXs (nasal 57.2 ± 4.3%, temporal 57.1 ± 4.5%) (both p < 0.005), while the mean central CoV (28.2 ± 2.5%) was higher than peripheral CoVs (nasal 25.8 ± 2.2%, temporal 26.1 ± 2.2%) (both p ≤ 0.001). Conclusions: : In young healthy non-CL wearers, the peripheral corneal endothelium displays a higher ECD and significantly better cell regularity (higher HEX and lower CoV) compared to the central cornea. A clinical evaluation of the corneal endothelium requires, therefore, a full characterization of the different areas.
Articolo in rivista - Articolo scientifico
Central and peripheral cornea; Corneal endothelium cell density; Polymegethism and polymorphism; Slit lamp biomicroscope
English
28-ago-2019
2020
43
2
149
153
none
Tavazzi, S., Cozza, F., Colciago, S., Zeri, F. (2020). Slit-lamp based assessment of peripheral versus central regions of the human corneal endothelium. CONTACT LENS & ANTERIOR EYE, 43(2), 149-153 [10.1016/j.clae.2019.08.002].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/262969
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
Social impact