The use of transcatheter aortic valve replacement (TAVR) for high-risk patients with aortic stenosis has rapidly increased during the past years. Accordingly, more and more patients are referred for a follow-up echocardiographic study after TAVR. However, the echocardiographic evaluation of patients who underwent TAVR places specific demands on echocardiographers. Furthermore, TAVR may be associated with new types of complications, which are frequently unrecognized or underestimated due to lack of familiarity with the normal and pathological appearance of TAVR. Therefore, this review summarizes the echocardiographic parameters describing the structural and functional status of bioprostheses used in TAVR, procedures taking into account their peculiar hemodynamics. We also describe the strengths and the limitations of echocardiography and of other imaging modalities in detecting long-term complications of TAVR (eg, infective endocarditis, thrombosis). The aim of this review was to serve as a guide for a structured echocardiographic follow-up of TAVR patients, as well as for the echocardiographic diagnosis of the procedure-associated complications.

Sokalskis, V., Muraru, D., Fraccaro, C., Napodano, M., D'Onofrio, A., Tarantini, G., et al. (2017). Echocardiographic follow-up after transcatheter aortic valve replacement. ECHOCARDIOGRAPHY, 34(2), 267-278 [10.1111/echo.13443].

Echocardiographic follow-up after transcatheter aortic valve replacement

Muraru D.;Badano L.
2017

Abstract

The use of transcatheter aortic valve replacement (TAVR) for high-risk patients with aortic stenosis has rapidly increased during the past years. Accordingly, more and more patients are referred for a follow-up echocardiographic study after TAVR. However, the echocardiographic evaluation of patients who underwent TAVR places specific demands on echocardiographers. Furthermore, TAVR may be associated with new types of complications, which are frequently unrecognized or underestimated due to lack of familiarity with the normal and pathological appearance of TAVR. Therefore, this review summarizes the echocardiographic parameters describing the structural and functional status of bioprostheses used in TAVR, procedures taking into account their peculiar hemodynamics. We also describe the strengths and the limitations of echocardiography and of other imaging modalities in detecting long-term complications of TAVR (eg, infective endocarditis, thrombosis). The aim of this review was to serve as a guide for a structured echocardiographic follow-up of TAVR patients, as well as for the echocardiographic diagnosis of the procedure-associated complications.
Articolo in rivista - Review Essay
aortic stenosis; aortic valve; echocardiography; endocarditis; thrombosis; transcatheter aortic valve replacement; Aortic Valve; Echocardiography; Follow-Up Studies; Humans; Kaplan-Meier Estimate; Postoperative Complications; Risk Assessment; Survival Rate; Treatment Outcome; Transcatheter Aortic Valve Replacement
English
2017
34
2
267
278
none
Sokalskis, V., Muraru, D., Fraccaro, C., Napodano, M., D'Onofrio, A., Tarantini, G., et al. (2017). Echocardiographic follow-up after transcatheter aortic valve replacement. ECHOCARDIOGRAPHY, 34(2), 267-278 [10.1111/echo.13443].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/257392
Citazioni
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 6
Social impact