This paper investigates the problem of plasma glucose regulation by means of intra-venous insulin administration. A model-based approach is followed, according to a discrete-time framework, since the available standard technology provides sampled glucose measurements and piece-wise constant insulin delivery devices. The digital control scheme is designed on the basis of an approximated sampled model, whose continuous-time original version is available in the recent literature, and has been shown to very well resemble real data on healthy subjects as well as on diabetic patients (both type 1 and type 2 Diabetes Mellitus). In silico simulations show the high performance of the proposed digital control law. ©2010 IEEE.

Palumbo, P., Pepe, P., Panunzi, S., De Gaetano, A. (2010). Digital closed-loop control of plasma glycemia. In Proceedings 49th IEEE Conference on Decision and Control (CDC10), Atlanta, Georgia, USA, December 2010 (pp.833-838) [10.1109/CDC.2010.5717997].

Digital closed-loop control of plasma glycemia

Palumbo P
Primo
;
2010

Abstract

This paper investigates the problem of plasma glucose regulation by means of intra-venous insulin administration. A model-based approach is followed, according to a discrete-time framework, since the available standard technology provides sampled glucose measurements and piece-wise constant insulin delivery devices. The digital control scheme is designed on the basis of an approximated sampled model, whose continuous-time original version is available in the recent literature, and has been shown to very well resemble real data on healthy subjects as well as on diabetic patients (both type 1 and type 2 Diabetes Mellitus). In silico simulations show the high performance of the proposed digital control law. ©2010 IEEE.
paper
Blood-glucose control; Input-output linearization; Time-delay systems
English
49th IEEE Conference on Decision and Control (CDC10)
2010
Proceedings 49th IEEE Conference on Decision and Control (CDC10), Atlanta, Georgia, USA, December 2010
978-1-4244-7746-3
2010
833
838
5717997
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=5717997
reserved
Palumbo, P., Pepe, P., Panunzi, S., De Gaetano, A. (2010). Digital closed-loop control of plasma glycemia. In Proceedings 49th IEEE Conference on Decision and Control (CDC10), Atlanta, Georgia, USA, December 2010 (pp.833-838) [10.1109/CDC.2010.5717997].
File in questo prodotto:
File Dimensione Formato  
2010-12 CDC-Atlanta - Digital glucose control - Speaker.pdf

Solo gestori archivio

Dimensione 257.02 kB
Formato Adobe PDF
257.02 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/246656
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
Social impact