PURPOSE: The aim of this work is to report a retrospective study of radiobiological indicators based on Dose-Volume Histograms analysis obtained by stereotactic radiotherapy treatments. METHODS AND MATERIALS: Fifty-five patients for a total of sixty-seven brain metastases with a mean target volume of 8.49 cc were treated by Dynamic Conformal Arc Therapy (DCAT) and Intensity-Modulated Stereotactic Radiotherapy (IMRST). The Delivered prescription dose was chosen on the basis of tumor size and location so as to ensure a 100% isodose coverage to the target volume. RESULTS: The treatment plans reported a mean value of 10% and 2.19% for the inhomogeneity and conformal index, respectively. The F factor showed we overdosed sixty-three patients delivering an additional 7% dose more than calculated values. The radiobiological parameters: TCP and NTCP showed a complete tumor control limiting the organs at risk damage. CONCLUSION: One goal of stereotactic radiotherapy is to design a treatment plan in which the steep dose gradient achievable minimizes the amount of radiation delivered outside the tumor region. This technique allows to deliver a much larger dose to the target without exceeding the radiation-related tolerance of normal tissues and improving patients' quality of life

Pasciuti, K., Iaccarino, G., Soriani, A., Bruzzaniti, V., Marzi, S., Gomellini, S., et al. (2008). DVHs evaluation in brain metastases stereotactic radiotherapy treatment plans. RADIOTHERAPY AND ONCOLOGY, 87(1), 110-115 [10.1016/j.radonc.2007.12.019].

DVHs evaluation in brain metastases stereotactic radiotherapy treatment plans

Arcangeli, S;
2008

Abstract

PURPOSE: The aim of this work is to report a retrospective study of radiobiological indicators based on Dose-Volume Histograms analysis obtained by stereotactic radiotherapy treatments. METHODS AND MATERIALS: Fifty-five patients for a total of sixty-seven brain metastases with a mean target volume of 8.49 cc were treated by Dynamic Conformal Arc Therapy (DCAT) and Intensity-Modulated Stereotactic Radiotherapy (IMRST). The Delivered prescription dose was chosen on the basis of tumor size and location so as to ensure a 100% isodose coverage to the target volume. RESULTS: The treatment plans reported a mean value of 10% and 2.19% for the inhomogeneity and conformal index, respectively. The F factor showed we overdosed sixty-three patients delivering an additional 7% dose more than calculated values. The radiobiological parameters: TCP and NTCP showed a complete tumor control limiting the organs at risk damage. CONCLUSION: One goal of stereotactic radiotherapy is to design a treatment plan in which the steep dose gradient achievable minimizes the amount of radiation delivered outside the tumor region. This technique allows to deliver a much larger dose to the target without exceeding the radiation-related tolerance of normal tissues and improving patients' quality of life
Articolo in rivista - Articolo scientifico
stereotactic radiotherapy ; brain metastases ; DVHs
English
2008
87
1
110
115
reserved
Pasciuti, K., Iaccarino, G., Soriani, A., Bruzzaniti, V., Marzi, S., Gomellini, S., et al. (2008). DVHs evaluation in brain metastases stereotactic radiotherapy treatment plans. RADIOTHERAPY AND ONCOLOGY, 87(1), 110-115 [10.1016/j.radonc.2007.12.019].
File in questo prodotto:
File Dimensione Formato  
Pasciuti K 08.pdf

Solo gestori archivio

Dimensione 259.85 kB
Formato Adobe PDF
259.85 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/221480
Citazioni
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
Social impact