Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA LE MODIFICHE in fondo alla pagina
Bicocca Open Archive
We present an updated description of the Planck Low Frequency Instrument (LFI) data processing pipeline, associated with the 2015 data release. We point out the places where our results and methods have remained unchanged since the 2013 paper and we highlight the changes made for the 2015 release, describing the products (especially timelines) and the ways in which they were obtained. We demonstrate that the pipeline is self-consistent (principally based on simulations) and report all null tests. For the first time, we present LFI maps in Stokes Q and U polarization. We refer to other related papers where more detailed descriptions of the LFI data processing pipeline may be found if needed.
Ade, P., Aghanim, N., Ashdown, M., Aumont, J., Baccigalupi, C., Ballardini, M., et al. (2016). Planck 2015 results: II. Low Frequency Instrument data processings. ASTRONOMY & ASTROPHYSICS, 594 [10.1051/0004-6361/201525818].
Planck 2015 results: II. Low Frequency Instrument data processings
Ade, P. A. R.;Aghanim, N.;Ashdown, M.;Aumont, J.;Baccigalupi, C.;Ballardini, M.;Banday, A. J.;Barreiro, R. B.;Bartolo, N.;Basak, S.;Battaglia, P.;Battaner, E.;Benabed, K.;Benoît, A.;Benoit Lévy, A.;Bernard, J. P.;Bersanelli, M.;Bielewicz, P.;Bock, J. J.;Bonaldi, A.;Bonavera, L.;Bond, J. R.;Borrill, J.;Bouchet, F. R.;Bucher, M.;Burigana, C.;Butler, R. C.;Calabrese, E.;Cardoso, J. F.;Castex, G.;Catalano, A.;Chamballu, A.;Christensen, P. R.;Colombi, S.;Colombo, L. P. L.;Crill, B. P.;Curto, A.;Cuttaia, F.;Danese, L.;Davies, R. D.;Davis, R. J.;DE BERNARDIS, Paolo;De Rosa, A.;De Zotti, G.;Delabrouille, J.;Dickinson, C.;Diego, J. M.;Dole, H.;Donzelli, S.;Doré, O.;Douspis, M.;Ducout, A.;Dupac, X.;Efstathiou, G.;Elsner, F.;Enßlin, T. A.;Eriksen, H. K.;Fergusson, J.;Finelli, F.;Forni, O.;Frailis, M.;Franceschet, C.;Franceschi, E.;Frejsel, A.;Galeotta, S.;Galli, S.;Ganga, K.;Giard, M.;Giraud Héraud, Y.;Gjerløw, E.;González Nuevo, J.;Górski, K. M.;Gratton, S.;Gregorio, A.;Gruppuso, A.;Hansen, F. K.;Hanson, D.;Harrison, D. L.;Henrot Versillé, S.;Herranz, D.;Hildebrandt, S. R.;Hivon, E.;Hobson, M.;Holmes, W. A.;Hornstrup, A.;Hovest, W.;Huffenberger, K. M.;Hurier, G.;Jaffe, A. H.;Jaffe, T. R.;Juvela, M.;Keihänen, E.;Keskitalo, R.;Kiiveri, K.;Kisner, T. S.;Knoche, J.;Krachmalnicoff, N.;Kunz, M.;Kurki Suonio, H.;Lagache, G.;Lähteenmäki, A.;Lamarre, J. M.;Lasenby, A.;Lattanzi, M.;Lawrence, C. R.;Leahy, J. P.;Leonardi, R.;Lesgourgues, J.;Levrier, F.;Liguori, M.;Lilje, P. B.;Linden Vørnle, M.;Lindholm, V.;López Caniego, M.;Lubin, P. M.;Macías Pérez, J. F.;Maggio, G.;Maino, D.;Mandolesi, N.;Mangilli, A.;Maris, M.;Martin, P. G.;Martínez González, E.;MASI, Silvia;Matarrese, S.;Mazzotta, P.;Mcgehee, P.;Meinhold, P. R.;MELCHIORRI, Alessandro;Mendes, L.;Mennella, A.;Migliaccio, M.;Mitra, S.;Montier, L.;Morgante, G.;Morisset, N.;Mortlock, D.;Moss, A.;Munshi, D.;Murphy, J. A.;Naselsky, P.;NATI, FEDERICO;Natoli, P.;Netterfield, C. B.;Nørgaard Nielsen, H. U.;Novikov, D.;Novikov, I.;Oppermann, N.;Paci, F.;Pagano, L.;Paoletti, D.;Partridge, B.;Pasian, F.;Patanchon, G.;Pearson, T. J.;Peel, M.;Perdereau, O.;Perotto, L.;Perrotta, F.;Pettorino, V.;PIACENTINI, Francesco;Pierpaoli, E.;Pietrobon, D.;Pointecouteau, E.;Polenta, G.;Pratt, G. W.;Prézeau, G.;Prunet, S.;Puget, J. L.;Rachen, J. P.;Rebolo, R.;Reinecke, M.;Remazeilles, M.;Renzi, A.;Rocha, G.;Romelli, E.;Rosset, C.;Rossetti, M.;Roudier, G.;Rubiño Martín, J. A.;Rusholme, B.;Sandri, M.;Santos, D.;Savelainen, M.;Scott, D.;Seiffert, M. D.;Shellard, E. P. S.;Spencer, L. D.;Stolyarov, V.;Sutton, D.;Suur Uski, A. S.;Sygnet, J. F.;Tauber, J. A.;Tavagnacco, D.;Terenzi, L.;Toffolatti, L.;Tomasi, M.;Tristram, M.;Tucci, M.;Tuovinen, J.;Türler, M.;Umana, G.;Valenziano, L.;Valiviita, J.;Van Tent, B.;Vassallo, T.;Vielva, P.;Villa, F.;Wade, L. A.;Wandelt, B. D.;Watson, R.;Wehus, I. K.;Wilkinson, A.;Yvon, D.;Zacchei, A;Zonca, A.
2016
Abstract
We present an updated description of the Planck Low Frequency Instrument (LFI) data processing pipeline, associated with the 2015 data release. We point out the places where our results and methods have remained unchanged since the 2013 paper and we highlight the changes made for the 2015 release, describing the products (especially timelines) and the ways in which they were obtained. We demonstrate that the pipeline is self-consistent (principally based on simulations) and report all null tests. For the first time, we present LFI maps in Stokes Q and U polarization. We refer to other related papers where more detailed descriptions of the LFI data processing pipeline may be found if needed.
Ade, P., Aghanim, N., Ashdown, M., Aumont, J., Baccigalupi, C., Ballardini, M., et al. (2016). Planck 2015 results: II. Low Frequency Instrument data processings. ASTRONOMY & ASTROPHYSICS, 594 [10.1051/0004-6361/201525818].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/217351
Citazioni
20
13
Social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 598/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.