CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils inCUORE-0.

Alduino, C., Alfonso, K., Artusa, D., Avignone, F., Azzolini, O., Bari, G., et al. (2017). Low energy analysis techniques for CUORE. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 77(12) [10.1140/epjc/s10052-017-5433-1].

Low energy analysis techniques for CUORE

Biassoni, M;Branca, A;Brofferio, C;Canonica, L;Capelli, S;Carniti, P;Cassina, L;Chiesa, D;Clemenza, M;Cremonesi, O
;
Dell’Oro, S;Faverzani, M;Ferri, E;Fiorini, E;Giachero, A;Gironi, L;Gotti, C;Nastasi, M;Nucciotti, A;Pattavina, L;Pavan, M;Pessina, G;Pozzi, S;Previtali, E;Sisti, M;Terranova, F;Zanotti, L;
2017

Abstract

CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils inCUORE-0.
Articolo in rivista - Articolo scientifico
Dark-Matter Candidates; Annual Modulation; Te-130
English
2017
77
12
857
open
Alduino, C., Alfonso, K., Artusa, D., Avignone, F., Azzolini, O., Bari, G., et al. (2017). Low energy analysis techniques for CUORE. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 77(12) [10.1140/epjc/s10052-017-5433-1].
File in questo prodotto:
File Dimensione Formato  
10281-187268.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 2.07 MB
Formato Adobe PDF
2.07 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/187268
Citazioni
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 15
Social impact