Recently there is a flourishing and notable interest in the crystalline scintillator material sodium iodide (NaI) as target for direct dark matter searches. This is mainly driven by the long-reigning contradicting situation in the dark matter sector: the positive evidence for the detection of a dark matter modulation signal claimed by the DAMA/LIBRA collaboration is (under so-called standard assumptions) inconsistent with the null-results reported by most of the other direct dark matter experiments. We present the results of a first prototype detector using a new experimental approach in comparison to conventional single-channel NaI scintillation light detectors: a NaI crystal operated as a scintillating calorimeter at milli-Kelvin temperatures simultaneously providing a phonon (heat) plus scintillation light signal and particle discrimination on an event-by-event basis. We evaluate energy resolution, energy threshold and further performance parameters of this prototype detector developed within the COSINUS R&D project

Angloher, G., Carniti, P., Cassina, L., Gironi, L., Gotti, C., Gütlein, A., et al. (2017). Results from the first cryogenic NaI detector for the COSINUS project. JOURNAL OF INSTRUMENTATION, 12(11) [10.1088/1748-0221/12/11/P11007].

Results from the first cryogenic NaI detector for the COSINUS project

Carniti, P.;Cassina, L.;Gironi, L.;Gotti, C.;Maino, M.;PAGNANINI, LORENZO;Pessina, G.;
2017

Abstract

Recently there is a flourishing and notable interest in the crystalline scintillator material sodium iodide (NaI) as target for direct dark matter searches. This is mainly driven by the long-reigning contradicting situation in the dark matter sector: the positive evidence for the detection of a dark matter modulation signal claimed by the DAMA/LIBRA collaboration is (under so-called standard assumptions) inconsistent with the null-results reported by most of the other direct dark matter experiments. We present the results of a first prototype detector using a new experimental approach in comparison to conventional single-channel NaI scintillation light detectors: a NaI crystal operated as a scintillating calorimeter at milli-Kelvin temperatures simultaneously providing a phonon (heat) plus scintillation light signal and particle discrimination on an event-by-event basis. We evaluate energy resolution, energy threshold and further performance parameters of this prototype detector developed within the COSINUS R&D project
Articolo in rivista - Articolo scientifico
Bolometers for dark matter research; Cryogenic detectors; Dark Matter detectors (WIMPs, axions, etc.); Instrumentation;
English
2017
12
11
P11007
none
Angloher, G., Carniti, P., Cassina, L., Gironi, L., Gotti, C., Gütlein, A., et al. (2017). Results from the first cryogenic NaI detector for the COSINUS project. JOURNAL OF INSTRUMENTATION, 12(11) [10.1088/1748-0221/12/11/P11007].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/184647
Citazioni
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 30
Social impact