Complementary information provided by Single Photon and Positron Emission Tomography (SPECT and PET) in nuclear cardiology allows a better comprehension of the physiopathology of the heart. In this work a surface matching registration technique is evaluated in the spatial correlation of SPECT and PET cardiac images. The method is based on matching correspondent anatomical surfaces extracted from transmission (TR) SPECT and PET studies, usually performed for attenuation correction. The accuracy of the technique was evaluated by phantom experiments and on patient data (201Tl SPECT and 13NH3 PET perfusion studies). An application of the method is presented for the correlation of SPECT 201Tl perfusion and PET 18FDG metabolic studies in the evaluation of myocardial viability

Gilardi, M., Rizzo, G., Savi, A., Landoni, C., Bettinardi, V., Rossetti, C., et al. (1998). Correlation of SPECT and PET cardiac images by a surface matching registration technique. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 22(5), 391-398 [10.1016/S0895-6111(98)00039-1].

Correlation of SPECT and PET cardiac images by a surface matching registration technique

GILARDI, MARIA CARLA;LANDONI, CLAUDIO;FAZIO, FERRUCCIO
1998

Abstract

Complementary information provided by Single Photon and Positron Emission Tomography (SPECT and PET) in nuclear cardiology allows a better comprehension of the physiopathology of the heart. In this work a surface matching registration technique is evaluated in the spatial correlation of SPECT and PET cardiac images. The method is based on matching correspondent anatomical surfaces extracted from transmission (TR) SPECT and PET studies, usually performed for attenuation correction. The accuracy of the technique was evaluated by phantom experiments and on patient data (201Tl SPECT and 13NH3 PET perfusion studies). An application of the method is presented for the correlation of SPECT 201Tl perfusion and PET 18FDG metabolic studies in the evaluation of myocardial viability
Articolo in rivista - Articolo scientifico
Image registration; Cardiac imaging; PET; SPECT
English
1998
22
5
391
398
none
Gilardi, M., Rizzo, G., Savi, A., Landoni, C., Bettinardi, V., Rossetti, C., et al. (1998). Correlation of SPECT and PET cardiac images by a surface matching registration technique. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 22(5), 391-398 [10.1016/S0895-6111(98)00039-1].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/16716
Citazioni
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 22
Social impact