Improvements in cryogenic thermal detector performances have triggered new generation experiments based on this devices. MiBeta detector had shown, during the last five years, the potential of a large mass cryogenic detector for long running time, good energy resolution, low energy threshold and low radioactive background experiment. Starting from this point a new very large cryogenic detector was proposed: CUORE (Cryogenic Underground Observatory for Rare Events). CUORE will be a segmented detector made with 1000 crystals of TeO2 of 5×5×5 cm3, for a total detector mass around 760 kg. Thanks to the high granularity a considerable improvement in background rejection can be reached using coincidence analysis between crystals. The main goal of CUORE will be the search of neutrinoless double beta decay of 130Te but also other studies are possible; in particular dark matter and solar axion searches. To prove the feasibility of CUORE a pilot experiment named CUORICINO was proposed and also founded. The estimated sensitivities of CUORICDMO and CUORE for WIMPs searches is here reported.

Beeman, J., Mcdonald, R., Hauler, E., Norman, E., Smith, A., Giuliani, A., et al. (2003). CUORICINO and CUORE. In The Identification of Dark Matter (pp.639-644) [10.1142/9789812791313_0093].

CUORICINO and CUORE

BROFFERIO, CHIARA;CAPELLI, SILVIA;CREMONESI, OLIVIERO;FIORINI, ETTORE;NUCCIOTTI, ANGELO ENRICO LODOVICO;PAVAN, MAURA;PESSINA, GIANLUIGI EZIO;PREVITALI, EZIO;SISTI, MONICA;ZANOTTI, LUIGI ERNESTO;
2003

Abstract

Improvements in cryogenic thermal detector performances have triggered new generation experiments based on this devices. MiBeta detector had shown, during the last five years, the potential of a large mass cryogenic detector for long running time, good energy resolution, low energy threshold and low radioactive background experiment. Starting from this point a new very large cryogenic detector was proposed: CUORE (Cryogenic Underground Observatory for Rare Events). CUORE will be a segmented detector made with 1000 crystals of TeO2 of 5×5×5 cm3, for a total detector mass around 760 kg. Thanks to the high granularity a considerable improvement in background rejection can be reached using coincidence analysis between crystals. The main goal of CUORE will be the search of neutrinoless double beta decay of 130Te but also other studies are possible; in particular dark matter and solar axion searches. To prove the feasibility of CUORE a pilot experiment named CUORICINO was proposed and also founded. The estimated sensitivities of CUORICDMO and CUORE for WIMPs searches is here reported.
slide + paper
Bolometers; Double Beta Decay; Te-130
English
Fourth International Workshop on The Identification of Dark Matter
2002
The Identification of Dark Matter
978-981-238-237-5
2003
639
644
none
Beeman, J., Mcdonald, R., Hauler, E., Norman, E., Smith, A., Giuliani, A., et al. (2003). CUORICINO and CUORE. In The Identification of Dark Matter (pp.639-644) [10.1142/9789812791313_0093].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/154133
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
Social impact