Purpose: The purpose of the article is to compare the diagnostic performance about radiation dose and image quality of low-dose CT with iterative reconstruction algorithm (iDose4) and standard-dose CT in the assessment of mesorectal fascia (MRF) invasion in rectal cancer patients. Materials and methods: Ninety-one patients with biopsy-proven primary rectal adenocarcinoma underwent CT staging: 42 underwent low-dose CT, 49 underwent standard CT protocol. Low-dose contrast-enhanced MDCT scans were performed on a 256 (ICT, Philips) scanner using 120 kV, automated mAs modulation, iDose4 iterative reconstruction algorithm. Standard-dose MDCT scans were performed on the same scanner with 120 kV, 200–300 mAs. All patients underwent a standard lower abdomen MR study (on 1.5T magnet), including multiplanar sequences, considered as reference standard. Diagnostic accuracy of MRF assessment was determined on CT images for both CT protocols and compared with MRI images. Dose-length product (DLP) and CT dose index (CTDI) calculated for both groups were compared and statistically analyzed. Results: Low-dose protocol with iDose4 showed high diagnostic quality in assessment of MRF with significant reduction (23%; p = 0.0081) of radiation dose (DLP 2453.47) compared to standard-dose examination (DLP 3194.32). Conclusions: Low-dose protocol combined with iDose4 reconstruction algorithm offers high-quality images, obtaining significant radiation dose reduction, useful in the evaluation of MRF involvement in rectal cancer patients.

Ippolito, D., Drago, S., Talei Franzesi, C., Casiraghi, A., Sironi, S. (2017). Diagnostic value of fourth-generation iterative reconstruction algorithm with low-dose CT protocol in assessment of mesorectal fascia invasion in rectal cancer: comparison with magnetic resonance. ABDOMINAL RADIOLOGY, 42(9), 2251-2260 [10.1007/s00261-017-1138-z].

Diagnostic value of fourth-generation iterative reconstruction algorithm with low-dose CT protocol in assessment of mesorectal fascia invasion in rectal cancer: comparison with magnetic resonance

Ippolito, D
;
Drago, SG;Talei Franzesi, CRGL;Casiraghi, AS;Sironi, S.
2017

Abstract

Purpose: The purpose of the article is to compare the diagnostic performance about radiation dose and image quality of low-dose CT with iterative reconstruction algorithm (iDose4) and standard-dose CT in the assessment of mesorectal fascia (MRF) invasion in rectal cancer patients. Materials and methods: Ninety-one patients with biopsy-proven primary rectal adenocarcinoma underwent CT staging: 42 underwent low-dose CT, 49 underwent standard CT protocol. Low-dose contrast-enhanced MDCT scans were performed on a 256 (ICT, Philips) scanner using 120 kV, automated mAs modulation, iDose4 iterative reconstruction algorithm. Standard-dose MDCT scans were performed on the same scanner with 120 kV, 200–300 mAs. All patients underwent a standard lower abdomen MR study (on 1.5T magnet), including multiplanar sequences, considered as reference standard. Diagnostic accuracy of MRF assessment was determined on CT images for both CT protocols and compared with MRI images. Dose-length product (DLP) and CT dose index (CTDI) calculated for both groups were compared and statistically analyzed. Results: Low-dose protocol with iDose4 showed high diagnostic quality in assessment of MRF with significant reduction (23%; p = 0.0081) of radiation dose (DLP 2453.47) compared to standard-dose examination (DLP 3194.32). Conclusions: Low-dose protocol combined with iDose4 reconstruction algorithm offers high-quality images, obtaining significant radiation dose reduction, useful in the evaluation of MRF involvement in rectal cancer patients.
Articolo in rivista - Articolo scientifico
Computed tomography; Magnetic resonance imaging; Mesorectal fascia; Reconstruction algorithm; Rectal cancer; Radiology, Nuclear Medicine and Imaging; Gastroenterology; Urology; Radiological and Ultrasound Technology
English
2017
42
9
2251
2260
none
Ippolito, D., Drago, S., Talei Franzesi, C., Casiraghi, A., Sironi, S. (2017). Diagnostic value of fourth-generation iterative reconstruction algorithm with low-dose CT protocol in assessment of mesorectal fascia invasion in rectal cancer: comparison with magnetic resonance. ABDOMINAL RADIOLOGY, 42(9), 2251-2260 [10.1007/s00261-017-1138-z].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/151231
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
Social impact