We propose an innovative, repeatable, and reliable experimental workflow to concentrate and detect environmental bacteria in drinking water using molecular techniques. We first concentrated bacteria in water samples using tangential flow filtration and then we evaluated two methods of environmental DNA extraction. We performed tests on both artificially contaminated water samples and real drinking water samples. The efficiency of the experimental workflow was measured through qPCR. The successful applicability of the high-throughput DNA sequencing (HTS) approach was demonstrated on drinking water samples. Our results demonstrate the feasibility of our approach in high-throughput-based studies, and we suggest incorporating it in monitoring strategies to have a better representation of the microbial community. In the recent years, HTS techniques have become key tools in the study of microbial communities. To make the leap from academic laboratories to the routine monitoring (e.g., water treatment plants laboratories), we here propose an experimental workflow suitable for the introduction of HTS as a standard method for detecting environmental bacteria.
Bruno, A., Sandionigi, A., Galimberti, A., Siani, E., Labra, M., Cocuzza, C., et al. (2017). One step forwards for the routine use of high-throughput DNA sequencing in environmental monitoring. An efficient and standardizable method to maximize the detection of environmental bacteria. MICROBIOLOGYOPEN, 6(1) [10.1002/mbo3.421].
One step forwards for the routine use of high-throughput DNA sequencing in environmental monitoring. An efficient and standardizable method to maximize the detection of environmental bacteria
BRUNO, ANTONIAPrimo
;SANDIONIGI, ANNASecondo
;GALIMBERTI, ANDREA;LABRA, MASSIMO;COCUZZA, CLEMENTINA ELVEZIA;FERRI, EMANUELEPenultimo
;CASIRAGHI, MAURIZIO
Ultimo
2017
Abstract
We propose an innovative, repeatable, and reliable experimental workflow to concentrate and detect environmental bacteria in drinking water using molecular techniques. We first concentrated bacteria in water samples using tangential flow filtration and then we evaluated two methods of environmental DNA extraction. We performed tests on both artificially contaminated water samples and real drinking water samples. The efficiency of the experimental workflow was measured through qPCR. The successful applicability of the high-throughput DNA sequencing (HTS) approach was demonstrated on drinking water samples. Our results demonstrate the feasibility of our approach in high-throughput-based studies, and we suggest incorporating it in monitoring strategies to have a better representation of the microbial community. In the recent years, HTS techniques have become key tools in the study of microbial communities. To make the leap from academic laboratories to the routine monitoring (e.g., water treatment plants laboratories), we here propose an experimental workflow suitable for the introduction of HTS as a standard method for detecting environmental bacteria.File | Dimensione | Formato | |
---|---|---|---|
a.29 - Bruno et al. MicrobiologyOpen 2016.pdf
accesso aperto
Dimensione
556.33 kB
Formato
Adobe PDF
|
556.33 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.