The Electronics system of experiments for the study of rare decays, such as the neutrino-less double beta decay, must be very stable over very long expected runs. We introduce our solution for the power supply of such an experiment, CUORE. In this case the power supply chain consists of a series of ACDCs, followed by DCDCs and then Linear Regulators. We emphasize here our approach to the DCDC regulation system that was designed with a complete rejection of the switching noise, across 100 MHz bandwidth. In the experimental layout the DCDC will be located far from the very front-end, with long connecting cables (10 m). We introduced our very simple and safe solution to prevent huge over-voltages, due to the energy stored in the inductance of the cables, generated after the release of accidental short circuits, so avoiding destructive effects. Some micro-controllers are present on every board and take care of the DCDC operation. These micro-controllers are managed from the control room, via CAN BUS protocol coupled via optical fibres. CUORE is an array of 1000 cryogenic detectors that will need 30 of our DCDCs.

Arnaboldi, C., Bau', A., Carniti, P., Cassina, L., Giachero, A., Gotti, C., et al. (2016). The supply voltage apparatus of the CUORE experiment. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 824, 340-342 [10.1016/j.nima.2015.09.101].

The supply voltage apparatus of the CUORE experiment

ARNABOLDI, CLAUDIO
Primo
;
BAU', ALESSANDRO
Secondo
;
CARNITI, PAOLO;CASSINA, LORENZO;GIACHERO, ANDREA;GOTTI, CLAUDIO;MAINO, MATTEO;PASSERINI, ANDREA
Penultimo
;
PESSINA, GIANLUIGI EZIO
Ultimo
2016

Abstract

The Electronics system of experiments for the study of rare decays, such as the neutrino-less double beta decay, must be very stable over very long expected runs. We introduce our solution for the power supply of such an experiment, CUORE. In this case the power supply chain consists of a series of ACDCs, followed by DCDCs and then Linear Regulators. We emphasize here our approach to the DCDC regulation system that was designed with a complete rejection of the switching noise, across 100 MHz bandwidth. In the experimental layout the DCDC will be located far from the very front-end, with long connecting cables (10 m). We introduced our very simple and safe solution to prevent huge over-voltages, due to the energy stored in the inductance of the cables, generated after the release of accidental short circuits, so avoiding destructive effects. Some micro-controllers are present on every board and take care of the DCDC operation. These micro-controllers are managed from the control room, via CAN BUS protocol coupled via optical fibres. CUORE is an array of 1000 cryogenic detectors that will need 30 of our DCDCs.
Articolo in rivista - Articolo scientifico
DCDC voltage supply; Low noise voltage supply; Power voltage supply;
DCDC voltage supply; Low noise voltage supply; Power voltage supply; Instrumentation; Nuclear and High Energy Physics
English
2016
824
340
342
none
Arnaboldi, C., Bau', A., Carniti, P., Cassina, L., Giachero, A., Gotti, C., et al. (2016). The supply voltage apparatus of the CUORE experiment. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 824, 340-342 [10.1016/j.nima.2015.09.101].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/133167
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
Social impact