Background: Hypertension guidelines recommend ambulatory blood pressure (ABP), central aortic pressure (CAP), and pulse wave velocity (PWV) as parameters for estimating blood pressure (BP) control and vascular impairment. Recent advances in technology have enabled devices to combine non-invasive estimation of these parameters over the 24-hour ABP monitoring. However, currently there is limited evidence on the usefulness of such an approach for routine hypertension management. Objective: We recently launched an investigator-initiated, international, multicenter, observational, prospective study, the Vascular health Assessment Of The Hypertensive patients (VASOTENS) Registry, aimed at (1) evaluating non-invasive 24-hour ABP and arterial stiffness estimates (through 24-hour pulse wave analysis, PWA) in hypertensive subjects undergoing ambulatory blood pressure monitoring (ABPM) for clinical reasons; (2) assessing the changes in estimates following treatment; (3) weighing the impact of 24-hour PWA on target organ damage and cardiovascular prognosis; (4) assessing the relationship between arterial stiffness, BP absolute mean level and variability, and prognosis; and (5) validating the use of a 24-hour PWA electronic health (e-health) solution for hypertension screening. Methods: Approximately 2000 subjects, referred to 20 hypertension clinics for routine diagnostic evaluation and follow-up of hypertension of any severity or stage, will be recruited. Data collection will include ABPM, performed with a device allowing simultaneous non-invasive assessment of 24-hour CAP and arterial stiffness (BPLab), and clinical data (including cardiovascular outcomes). As recommended by current guidelines, each patient will be followed-up with visits occurring at regular intervals (ideally every 6 months, and not less than once a year depending on disease severity). A Web-based telemedicine platform (THOLOMEUS) will be used for data collection. The use of the telemedicine system will allow standardized and centralized data collection, data validation by experts and counseling to remote centers, setup and maintenance of the Registry, and prompt data analysis. Results: First follow-up results are expected to be available in the next 2 years. Conclusions: The results of the VASOTENS Registry will help define the normalcy thresholds for current and future indices derived from 24-hour PWA, according to outcome data, and will also provide supporting evidence for the inclusion of this type of evaluation in hypertension management

Omboni, S., Posokhov, I., Parati, G., Avolio, A., Rogoza, A., Kotovskaya, Y., et al. (2016). Vascular Health Assessment of The Hypertensive Patients (VASOTENS) Registry: Study Protocol of an International, Web-Based Telemonitoring Registry for Ambulatory Blood Pressure and Arterial Stiffness. JMIR RESEARCH PROTOCOLS, 5(2) [10.2196/resprot.5619].

Vascular Health Assessment of The Hypertensive Patients (VASOTENS) Registry: Study Protocol of an International, Web-Based Telemonitoring Registry for Ambulatory Blood Pressure and Arterial Stiffness

Parati, G;
2016

Abstract

Background: Hypertension guidelines recommend ambulatory blood pressure (ABP), central aortic pressure (CAP), and pulse wave velocity (PWV) as parameters for estimating blood pressure (BP) control and vascular impairment. Recent advances in technology have enabled devices to combine non-invasive estimation of these parameters over the 24-hour ABP monitoring. However, currently there is limited evidence on the usefulness of such an approach for routine hypertension management. Objective: We recently launched an investigator-initiated, international, multicenter, observational, prospective study, the Vascular health Assessment Of The Hypertensive patients (VASOTENS) Registry, aimed at (1) evaluating non-invasive 24-hour ABP and arterial stiffness estimates (through 24-hour pulse wave analysis, PWA) in hypertensive subjects undergoing ambulatory blood pressure monitoring (ABPM) for clinical reasons; (2) assessing the changes in estimates following treatment; (3) weighing the impact of 24-hour PWA on target organ damage and cardiovascular prognosis; (4) assessing the relationship between arterial stiffness, BP absolute mean level and variability, and prognosis; and (5) validating the use of a 24-hour PWA electronic health (e-health) solution for hypertension screening. Methods: Approximately 2000 subjects, referred to 20 hypertension clinics for routine diagnostic evaluation and follow-up of hypertension of any severity or stage, will be recruited. Data collection will include ABPM, performed with a device allowing simultaneous non-invasive assessment of 24-hour CAP and arterial stiffness (BPLab), and clinical data (including cardiovascular outcomes). As recommended by current guidelines, each patient will be followed-up with visits occurring at regular intervals (ideally every 6 months, and not less than once a year depending on disease severity). A Web-based telemedicine platform (THOLOMEUS) will be used for data collection. The use of the telemedicine system will allow standardized and centralized data collection, data validation by experts and counseling to remote centers, setup and maintenance of the Registry, and prompt data analysis. Results: First follow-up results are expected to be available in the next 2 years. Conclusions: The results of the VASOTENS Registry will help define the normalcy thresholds for current and future indices derived from 24-hour PWA, according to outcome data, and will also provide supporting evidence for the inclusion of this type of evaluation in hypertension management
Articolo in rivista - Articolo scientifico
arterial stiffness; augmentation index; blood pressure telemonitoring; central aortic pressure; hypertension; pulse wave velocity
English
2016
5
2
e137
open
Omboni, S., Posokhov, I., Parati, G., Avolio, A., Rogoza, A., Kotovskaya, Y., et al. (2016). Vascular Health Assessment of The Hypertensive Patients (VASOTENS) Registry: Study Protocol of an International, Web-Based Telemonitoring Registry for Ambulatory Blood Pressure and Arterial Stiffness. JMIR RESEARCH PROTOCOLS, 5(2) [10.2196/resprot.5619].
File in questo prodotto:
File Dimensione Formato  
10281-131614.pdf

accesso aperto

Tipologia di allegato: Publisher’s Version (Version of Record, VoR)
Dimensione 451.37 kB
Formato Adobe PDF
451.37 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/131614
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 17
Social impact