CUORE is a proposed tightly packed array of 1000 TeO<sub>2</sub> bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers×5 towers, each containing 10 layers of four crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double-beta decay of <sup>130</sup>Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3×3×6 cm<sup>3</sup> of 340 g has been completed, and a single CUORE tower is being constructed as a smaller-scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported. © 2003 Elsevier B.V. All rights reserved.

Arnaboldi, C., Avignone, F., Beemanc, J., Barucci, M., Balata, M., Brofferio, C., et al. (2004). CUORE: a cryogenic underground observatory for rare events. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 518(3), 775-798 [10.1016/j.nima.2003.07.067].

CUORE: a cryogenic underground observatory for rare events

ARNABOLDI, CLAUDIO;BROFFERIO, CHIARA;CAPELLI, SILVIA;Cremonesi, O;FIORINI, ETTORE;GIULIANI, ANDREA;GORLA, PAOLO;NUCCIOTTI, ANGELO ENRICO LODOVICO;PAVAN, MAURA;Previtali, E;SISTI, MONICA;ZANOTTI, LUIGI ERNESTO;
2004

Abstract

CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers×5 towers, each containing 10 layers of four crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double-beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3×3×6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller-scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported. © 2003 Elsevier B.V. All rights reserved.
Articolo in rivista - Articolo scientifico
English
2004
518
3
775
798
open
Arnaboldi, C., Avignone, F., Beemanc, J., Barucci, M., Balata, M., Brofferio, C., et al. (2004). CUORE: a cryogenic underground observatory for rare events. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 518(3), 775-798 [10.1016/j.nima.2003.07.067].
File in questo prodotto:
File Dimensione Formato  
0212053v1-1.pdf

accesso aperto

Tipologia di allegato: Submitted Version (Pre-print)
Dimensione 630.04 kB
Formato Adobe PDF
630.04 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10281/12618
Citazioni
  • Scopus 305
  • ???jsp.display-item.citation.isi??? 272
Social impact